西门子PLC控制电缆
西门子PLC控制电缆
Version | Description | Connector size | Cross-section | D max | r static | r dynamic | For motor | Article No. |
---|---|---|---|---|---|---|---|---|
|
|
| mm2 | mm (in) | mm (in) | mm (in) | (Possible for 1FS2 with Q1x) | (Length code see table) |
Pre-assembled OCC extension cable MOTION-CONNECT 500 for predominantly fixed routing with SPEED-CONNECT connectors | M12 | 0.38 | 9.7 (0.38) | 23.5 (0.93) | 195 (7.68) | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX5002-8QE04-1❑❑❑ | |
M17 | 0.75 | 10.5 (0.41) | 25.5 (1.00) | 195 (7.68) | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX5002-8QE08-1❑❑❑ | ||
M23 | 1.5 | 12.7 (0.50) | 30.7 (1.21) | 195 (7.68) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX5002-8QE11-1❑❑❑ | ||
M23 | 2.5 1) | 13.7 (0.54) | 30.7 (1.21) | 195 (7.68) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX5002-8QE21-1❑❑❑ | ||
Pre-assembled OCC extension cable MOTION-CONNECT 800PLUS for use with cable carriers with SPEED-CONNECT connectors | M12 | 0.38 | 9.7 (0.38) | 28.2 (1.11) | 38 (1.50) | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX8002-8QE04-1❑❑❑ | |
M17 | 0.75 | 10.5 (0.41) | 30.6 (1.20) | 38 (1.50) | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX8002-8QE08-1❑❑❑ | ||
M23 | 1.5 | 12.7 (0.50) | 36.9 (1.45) | 92.2 (3.63) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX8002-8QE11-1❑❑❑ | ||
M23 | 2.5 1) | 13.7 (0.54) | 39.9 (1.57) | 99.7 (3.93) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX8002-8QE21-1❑❑❑ | ||
| Partially assembled OCC extension cable MOTION-CONNECT 500 for predominantly fixed routing with SPEED-CONNECT connectors (male contacts inserted on the converter side, insulator and connector enclosure included separately in the package)2) | M12 | 0.38 | 9.7 (0.38) | 23.5 (0.93) | 195 (7.68) | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX5012-8QE04-1❑❑❑ |
M17 | 0.75 | 10.5 (0.41) | 25.5 (1.00) | 195 (7.68) | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX5012-8QE08-1❑❑❑ | ||
M23 | 1.5 | 12.7 (0.50) | 30.7 (1.21) | 195 (7.68) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX5012-8QE11-1❑❑❑ | ||
M23 | 2.5 1) | 13.7 (0.54) | 30.7 (1.21) | 195 (7.68) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX5012-8QE21-1❑❑❑ | ||
Partially assembled OCC extension cable MOTION-CONNECT 800PLUS for use with cable carriers with SPEED-CONNECT connectors (male contacts inserted on the converter side, insulator and connector enclosure included separately in the package)2) | M12 | 0.38 | 9.7 (0.38) | 28.2 (1.11) | 38 (1.50) | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX8012-8QE04-1❑❑❑ | |
M17 | 0.75 | 10.5 (0.41) | 30.6 (1.20) | 38 (1.50) | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX8012-8QE08-1❑❑❑ | ||
M23 | 1.5 | 12.7 (0.50) | 36.9 (1.45) | 92.2 (3.63) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX8012-8QE11-1❑❑❑ | ||
M23 | 2.5 1) | 13.7 (0.54) | 39.9 (1.57) | 99.7 (3.93) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX8012-8QE21-1❑❑❑ |
1) For increased requirement regarding routing type and ambient temperature. See tables in the section MOTION-CONNECT connection systems > Further info > Current-carrying capacity and derating factors.
2) Special tools are required for the assembly of the extension cable. For more information, see the installation instructions.
OCC components for customer assembly
Version | Description | Cross-section | For motor | Article No. |
---|---|---|---|---|
|
| mm2 | (Possible for 1FS2 with Q1x) | (Length code see table) |
Sold by the meter, OCC cable MOTION-CONNECT 500 For the self assembly of motor connection or extension cables MOTION-CONNECT 500 for predominantly fixed routing | 0.38 | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX5008-1BE04-❑❑A0 | |
0.75 | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX5008-1BE08-❑❑A0 | ||
1.5 | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX5008-1BE11-❑❑A0 | ||
2.5 1) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX5008-1BE21-❑❑A0 | ||
Sold by the meter, OCC cable MOTION-CONNECT 800PLUS For the self assembly of motor connection or extension cables MOTION-CONNECT 800PLUS for use with cable carriers | 0.38 | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX8008-1BE04-❑❑A0 | |
0.75 | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX8008-1BE08-❑❑A0 | ||
1.5 | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX8008-1BE11-❑❑A0 | ||
2.5 1) | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 | 6FX8008-1BE21-❑❑A0 | ||
Sold by the meter, OCC cable MOTION-CONNECT 400 *) For the self assembly of motor connection or extension cables MOTION-CONNECT 400 for fixed routing | 0.75 | 1FS2104, 1FS2105 | 6FX4008-1BE08-❑❑A0 | |
1.5 | 1FS2106, 1FS2208 | 6FX4008-1BE11-❑❑A0 | ||
Motor-side M12 SPEED-CONNECT connector 10‑pole, including all socket contacts | 0.38 | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX2003-0LU64 | |
Motor-side M17 SPEED-CONNECT connector 10‑pole, including all socket contacts | 0.75 | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX2003-0LU54 | |
Motor-side M23 SPEED-CONNECT connector 10‑pole, including all socket contacts | 1.5 and 2.5 | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX2003-0LU34 | |
M12 SPEED-CONNECT connector with male thread for extension cable 10‑pole, including all pin contacts | 0.38 | 1FK2102, 1FK2 . 03‑ . . G 1FT2102, 1FT2 . 03‑ . . G | 6FX2003-0LA64 | |
M17 SPEED-CONNECT connector with male thread for extension cable 10‑pole, including all pin contacts | 0.75 | 1FK2103‑ . . H, 1FK2203‑ . . K, 1FK2 . 04, 1FK2 . 05 1FT2103‑ . . H, 1FT2203‑ . . K, 1FT2 . 04, 1FT2 . 05 1FS2104, 1FS2105 | 6FX2003-0LA54 | |
M23 SPEED-CONNECT connector with male thread for extension cable 10‑pole, including all pin contacts | 1.5 and 2.5 | 1FK2 . 06, 1FK2208, 1FK2210 1FT2 . 06, 1FT2208, 1FT2210 1FS2106, 1FS2208 | 6FX2003-0LA34 | |
Siemens IX ** connector on the converter side Device version in insulation displacement method for field assembly |
| – | 6FX2003-0DE01 | |
Shield clamp For attaching the connection cables to the shield plate of the converter |
|
|
| |
For pre-assembled cables with M12 and M17 plugs |
| – | 6FX2003-7EX10 | |
For pre-assembled cables with M23 plugs |
| – | 6FX2003-7EX11 |
*) Available soon.
1) For increased requirement regarding routing type and ambient temperature. See tables in the section MOTION-CONNECT connection systems > Further info > Current-carrying capacity and derating factors.
控制电缆
西门子PLC模块代理商