西门子PLC卡件6ES7288-3AE04-0AA0
西门子PLC卡件6ES7288-3AE04-0AA0
3SF1 行程开关可直接通过 AS-Interface 总线系统连接,实现安全通信。该安全功能就没有必要再按照惯例进行接线。
通过 3SF1 行程开关,ASIsafe 电子组件可以集成到开关外壳中。
模块化系统中选型举例
模块化系统
3SF11.4 和 3SF12.4 系列行程开关具有模块化结构设计,由不同形式的基本开关和按钮头(需单订购)组成。得益于开关的模块化设计,终用户可以从为数众多的型号中选择适合自己应用的正确解决方案,并在很短时间内自行安装。
设计
3SF1 开关具有各种外壳尺寸:
塑料和金属外壳,符合标准 EN 50047,31 mm 宽,带 M12 插头
根据 EN 50041,塑料外壳,40 mm 宽,带 M12 插头
塑料外壳,50 mm 宽,带 M12 插头和 M12 插座
金属外壳,56 mm 宽,带 M12 插头和 M12 插座
显示
该开关系列配有带三个 LED 的状态显示屏:
LED 1(黄色):F-IN1
LED 2(黄色):F-IN2
LED 3(绿/红):AS-i/FAULT
连接
到 AS-Interface 的连接是通过一个连接到黄色 AS-Interface 总线电缆的 4 较 M12 插头式连接器(塑料型)完成的。
宽外壳(50 或 56 mm)还具有用于连接*二个行程开关的 M12 接口。因此可以达到符合 EN ISO 13849-1 的 Category 4 D。
The 3SF1 safety switches offer:
ASIsafe electronics integrated in the enclosure, with low power consumption < 60 mA
An extensive range of actuators
Status display with three LEDs
Can be integrated easily via TIA Portal
With the standard position switches, mechanical positions of moving machine parts are converted into electrical **s. Through their modular and uniform design and large number of variants, the devices can comply with practically all requirements in industry.
Devices are available with enclosure versions to suit the particular ambient conditions. Different control tasks can be performed with the contact blocks best suited for the particular purpose. And many different actuator variants are available to match the mechanical configuration of the moving machine parts. Dimensions, fixing points and characteristics are largely in accordance with the EN 50041 or EN 50047 standards.
The devices are suitable for use in any climate.
The switches comply with IEC 60947‑1 (Low-Voltage Controlgear, General) and IEC 60947‑5‑1 (Electromechanical Control Circuit Devices).
The mechanical design of the switch corresponds to the requirements of the fail-safe principle according to ISO 14119.
AS-Interface according to IEC 62026‑2
The 3SF1 position switches are approved according to UL 508, UL 50 and UL 746-C.
Standard IEC 60947‑5‑1 requires positive opening of the NC contacts. In other words, for the purposes of personal safety, the assured opening of NC contacts is expressly stipulated for the electrical equipment of machines in all safety circuits and marked in accordance with the standard IEC 60947‑5‑1 with the symbol (→).
With a 3SF1 safety switch with (→), SIL 2 according to IEC 2061/IEC 61508 or PL c according to ISO 13849‑1 can be attained if the corresponding fail-safe evaluation units are selected from the ASIsafe program and correctly installed.
If a second 3SF1 safety switch with (→) is used, SIL 3/PL e can be attained.
Safety Evaluation in the TIA Selection Tool
The safety evaluation for the standards IEC 62061 and ISO 13849-1 is performed quickly and easily, directly in the TIA Selection Tool. In addition to the fast and safe calculation of machine safety functions – from the definition of the system structure to the selection of components – this enables shared data management during all project phases. Take the next step in the digital design of machinery and equipment with Safety Evaluation in the TIA Selection Tool.
In addition, the functionalities of the proven Safety Evaluation Tool are still available. It determines the achieved safety integrity (SIL/PL) step-by-step. You receive the results as a standards-compliant report that can be integrated in the documentation as proof of safety.
For more information see www./safety-evaluation.
Type |
| 3SF11.., 3SF12.. |
---|---|---|
General data |
|
|
Standards |
| IEC 60947‑5‑1, ISO 14119 |
Data according to AS-Interface specification |
|
|
I/O configuration/ID configuration |
| 0/B |
ID1 code/ID2 code (hex) |
| F/F |
Power consumption, overall | mA | ≤ 60 |
Inputs |
|
|
Low ** range |
| Contact open |
High ** range |
| Contact closed, Iin dynamic (Ipeak ≥ 5 mA) |
Status display |
| Green/red dual LED |
Rated impulse withstand voltage U imp | kV | 0.6 |
EMC immunity |
|
|
IEC 61000-1-2 | kV | 4 |
IEC 61000-4-3 | V/m | 10 |
IEC 61000-4-4 (A/B) | kV | 1/2 |
Mechanical endurance |
|
|
Basic switch |
| 15 x 106 operating cycles |
With separate actuator, 3SF1...‑..V.. |
| 1 x 106 operating cycles |
PFH value Probability of failure upon request of the safety function, with 1 actuation per hour and B10 = 5 x 106 |
|
|
Basic switch | 1/h | 4 x 10-9 |
With separate actuator, 3SF1...‑..V.. | 1/h | 2 x 10-9 |
Hinge switches, 3SF1...-..U.. | 1/h | 2 x 10-9 |
Shock resistance according to IEC 60068‑2‑27 | g/ms | 30/11 |
Type |
| 3SF1234 | 3SF1134 | 3SF1244 | 3SF1214 | 3SF1114 | 3SF1124 |
---|---|---|---|---|---|---|---|
Enclosures |
|
| |||||
Material |
| Ultramid A3X2G7 | Zinc die-casting GD‑ZnAl4Cu1 | ||||
Width | mm | 31 | 40 | 50 | 31 | 40 | 56 |
Dimensions according to EN |
| EN 50047 | EN 50041 | -- | EN 50047 | EN 50041 | -- |
Degree of protection according to IEC 60529 |
| IP65 | IP66/IP67 | ||||
Ambient temperature |
|
| |||||
During operation | °C | -25 ... +60 | |||||
Storage, transport | °C | -40 ... +80 | |||||
Mounting position | | Any |
M12 device plug, 4-pole | M12 socket, 4-pole |
---|---|
1 ASi + | 1 Channel 2 |
2 Not assigned | 2 Channel 2 |
3 ASi – | 3 Not assigned |
4 Not assigned | 4 Not assigned |
3SF1 safety switch with AS‑i and LED status displays
Status display (operating state)
LED | No voltage on AS-Interface chip | Communication OK | Communication failed | Slave has address "0" |
---|---|---|---|---|
AS‑i/Fault (GN/RD/YE) |
Safe inputs
LED | Not actuated | Actuated | ||
---|---|---|---|---|
F-IN1 (YE) | -- | -- | ||
F-IN2 (YE) | -- | -- |
西门子PLC卡件6ES7288-3AE04-0AA0 西门子PLC卡件6ES7288-3AE04-0AA0