6ES7288-3AT04-0AA0
6ES7288-3AT04-0AA0
The SIMATIC ET 200pro FC‑2 distributed frequency converter is a compact frequency converter for standard drives which has the design of a SIMATIC ET 200pro module. Each SIMATIC ET 200pro FC‑2 frequency converter includes both the Control Unit as well as the Power Module in one unit. In addition, there is a backplane bus module for integrating the frequency converter in the SIMATIC ET 200pro system bus.
SIMATIC ET 200pro FC‑2 frequency converter
The SIMATIC ET 200pro FC‑2 frequency converter supplements the SIMATIC ET 200pro system range with distributed, speed-controlled drives. The frequency converter offers, in combination with the other modules of the modular SIMATIC ET 200pro system, solutions which have been exactly tailored to the plant/system and allows, through the combination of several frequency converters in one distributed station, ideal solutions when drives are operated in the same area or for the same purposes.
SIMATIC ET 200pro station with two SIMATIC ET 200pro FC‑2 converters
It is completely embedded in the SIMATIC ET 200pro system and offers all the system advantages such as cabinet-free installation, easy mounting on the module rack, reduction of the wiring outlay due to self-assembling communication and supply rails in the backplane bus, comprehensive diagnostic mechanisms and high availability thanks to replaceability without affecting other modules in the SIMATIC ET 200pro station.
The certified STO safety function integrated as standard ensures that persons and machines are protected from the dangerous movement of machines. Integration of the safety system into the drive also simplifies the machine architecture and supports system-wide diagnostics.
Active and dynamic braking of the motor is possible without incurring any additional costs. The generated braking energy is fed back into the power supply, so there is no need for a braking chopper and braking resistors. To ensure full motor protection, a temperature sensor of the PTC type, bimetal, KTY or Pt1000 can be connected. The integrated 180 V DC brake control at 400 V line voltage (Uline × 0.45 = brake voltage) allows the direct activation of a motor holding brake and makes a rectifier in the motor terminal box superfluous.
In combination with an SD memory card, the slot for the optional memory card can be used to save the parameter settings in order to facilitate fast replacement of modules with automatic reparameterization.
SIMATIC ET 200pro FC‑2 frequency converters use the control modes frequency control and sensorless vector control. The SIMATIC ET 200pro FC‑2 frequency converter also supports torque control, for example, for applications with mechanically coupled drives. The innovative power unit concept capable of energy recovery helps save energy.
Options for parameter assignment:
STARTER, the graphical parameterization tool for Siemens drives
The fieldbus
A point-to-point connection via a mini USB interface
The optical interface for connection of an IOP-2 Handheld
A parameter set download from the SIMATIC controller is also possible.
The distributed SIMATIC ET 200pro FC-2 frequency converters feature the following interfaces as standard:
Line supply connection via Q4/2 (socket)
Motor connection via Q8 (connector) including control of the motor brake and temperature sensor
Power output via Q4/2 (connector) for looping the 400 V 3 AC further to a subsequent frequency converter or motor starter from the SIMATIC ET 200pro system
Connection example for SIMATIC ET 200pro FC-2
| Article No. |
---|---|
SIMATIC ET 200pro FC‑2 frequency converter with integrated safety function STO (Safe Torque Off) | 6SL3514-1KE13-5AE0 |
Backplane bus module for mounting the frequency converter (absolutely essential for operation of the converter) | 6SL3260-2TA00-0AA0 |
Distributed frequency converter | SIMATIC ET 200pro FC-2 | ||||
---|---|---|---|---|---|
Selection features | |||||
Integrated safety functions acc. to IEC 61508 SIL 2 and EN ISO 13849-1 PL d and Category 3 | Safe Torque Off (STO) Control of the integrated safety function via the Safety Local isolator module F-RSM or via F-Switch PROFIsafe | ||||
Electrical specifications | |||||
Line voltage | 380 ... 480 V 3 AC ±10 % | ||||
Power |
| ||||
With an ambient temperature of 0 ... 55 °C (32 °F ... 131 °F) | 1.1 kW | ||||
With an ambient temperature of 0 ... 45 °C (32 °F ... 113 °F) | 1.5 kW | ||||
Rated input current/output current |
| ||||
With an ambient temperature of 0 ... 55 °C (32 °F ... 131 °F) | 2 A/3.5 A | ||||
With an ambient temperature of 0 ... 45 °C (32 °F ... 113 °F) | 2.5 A/3.9 A | ||||
Line frequency | 47 ... 63 Hz | ||||
Overload capability | Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s | ||||
Output frequency | 0 ... 550 Hz | ||||
Pulse frequency | 4 kHz (standard), 4 ... 16 kHz (in 2-kHz increments) | ||||
Standard SCCR | 10 kA | ||||
Skipped frequency range | 1, parameterizable | ||||
Converter efficiency | 95 ... 97 % | ||||
Interfaces | Connection to PROFIBUS and PROFINET over the SIMATIC ET 200pro backplane bus Mini USB interface for commissioning via PC (as from STARTER V4.4 plus SSP) Optical interface for commissioning via the IOP-2 Handheld Slot for an optional memory card (SD) for uploading or downloading parameter settings. Facilitates easy device replacement. PTC, bimetal, KTY84, Pt1000 interface for motor temperature monitoring | ||||
Functions | |||||
Open-loop/closed-loop control methods | V/f control – linear (M ~ n) with/without flux current control (FCC), quadratic (M ~ n2) or parameterizable Vector control – sensorless Closed-loop torque control | ||||
Operating functions | Jogging BICO technology Automatic restart following interruptions in operation due to a power failure Smooth connection of converter to rotating motor | ||||
Braking functions | Integrated regenerative feedback functionality Control of an electromagnetic holding brake | ||||
Integrated brake control supplies DC power supply to the brake | |||||
Line voltage | 380 V AC | 400 V AC | 440 V AC | 480 V AC | |
Rectified brake voltage | 171 V DC | 180 V DC | 198 V DC | 216 V DC | |
Recommended brake coil voltage for Siemens motors | 170 ... 200 V DC | 170 ... 200 V DC | 184 ... 218 V DC | 184 ... 218 V DC | |
Disconnection on the DC side permits "fast" braking. | |||||
Protection functions | Undervoltage Overvoltage Ground fault Short-circuit Stall protection Thermal motor protection (I2t or sensor) Converter overtemperature Motor blocking protection Phase failure detection | ||||
Connectable motors | Low-voltage asynchronous (induction) motors Motor cable lengths: max. 15 m (49 ft) (shielded) | ||||
Mechanical specifications | |||||
Degree of protection | IP65 | ||||
Operating temperature | 0 ... 55 °C (32 ... 131 °F) | ||||
Mounting position | Vertical wall mounting (vertical alignment of the cooling fins) | ||||
Dimensions (W × H × D) | 155 mm × 246 mm × 248 mm (6.10 in × 9.69 in × 9.76 in) | ||||
Weight, approx. | 4 kg (8.8 lb) | ||||
Standards | |||||
Certificates of suitability | UL508C, cUL, CE, UKCA, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU |
IOP-2 Handheld for mobile use
The IOP-2 Handheld Intelligent Operator Panel is a very user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120D and SIMATIC ET 200pro FC-2 distributed converters.
The IOP-2 Handheld supports both newcomers and drive experts. Thanks to the membrane keyboard with a central sensor control field, the high-contrast color displays, the menu-based operation and the application wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list – as the parameters are displayed in plain text, and explanatory help texts and a parameter filtering function are provided.
Application wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There is a basic commissioning wizard for general commissioning.
Up to two process values can be graphically visualized and up to four process values can be numerically visualized on the status screen/display. Process values can also be displayed in technological units.
The IOP-2 Handheld supports series commissioning of identical drives. For this purpose, a parameter list can be copied from a frequency converter into the IOP-2 Handheld and downloaded into other drive units of the same type as required.
In addition to the IOP-2, the IOP-2 Handheld includes a housing with rechargeable batteries, a charging unit, an RS232 connecting cable, and a USB cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 10 hours.
To connect the IOP-2 Handheld to SINAMICS G120D and SIMATIC ET 200pro FC-2, the RS232 connecting cable with optical interface is required in addition.
Updating the IOP-2 Handheld
The IOP-2 Handheld can be updated and expanded using the integrated USB interface.
Data to support future drive systems can be transferred from the PC to the IOP-2 Handheld. Further, the USB interface allows user langes and wizards that will become available in the future to be subsequently downloaded and the firmware to be updated for the IOP-2 Handheld 1).
1) Information on updates for the IOP-2 Handheld is available at
Description | Article No. |
---|---|
IOP-2 Handheld For use with Included in the scope of delivery: IOP-2 Handheld housing Rechargeable batteries (4 × AA) Charging unit (international) RS232 connecting cable USB cable | 6SL3255-0AA00-4HA1 |
RS232 connecting cable 2.5 m (8.20 ft) long, | 3RK1922-2BP00 |
| IOP-2 Handheld |
---|---|
Display | High-contrast color display, a variety of display options |
Resolution | 320 × 240 pixels |
Operator panel | Membrane keyboard with central sensor control field |
Operating langes | English, German, French, Italian, Spanish, Portuguese, Dutch, Swedish, Finnish, Russian, Czech, Polish, Turkish, Chinese Simplified |
Ambient temperature |
|
During transport and storage | -20 ... +55 °C (-4 ... +131 °F) |
During operation | 0 ... 40 °C (32 ... 104 °F) |
Humidity | Relative humidity < 95 %, non-condensing |
Degree of protection | IP20 |
Dimensions (H × W × D) | 195.04 × 70 × 37.58 mm (7.68 × 2.76 × 1.48 in) |
Weight, approx. | 0.724 kg (1.6 lb) |
Compliance with standards | CE, UKCA, RCM, cULus, EAC, KC-REM-S49-SINAMICS |
SINAMICS SD memory card
The parameter settings of the converter and the firmware can be stored on the optional SINAMICS SD memory card. When service is required, the data are automatically downloaded from the memory card in the converter and the system is ready for use again without further interventions.
Parameter settings can be written from the memory card to the converter or saved from the converter to the memory card.
Up to 100 parameter sets can be stored.
The memory card supports series commissioning without the use of the Intelligent Operator Panel IOP-2 Handheld or the STARTER commissioning tool.
If firmware is stored on the memory card and a Control Unit is installed, the firmware can be upgraded/downgraded during power-up 1)
Note:
The memory card is optional, but it facilitates converter replacement.
1) You can find more information about firmware upgrades/downgrades on the internet at
Description |
| Article No. |
---|---|---|
SINAMICS SD card |
| 6SL3054-4AG00-2AA0 |
Optional firmware memory cards | ||
SINAMICS SD card (Multicard V4.7 SP13) |
| 6SL3054-7TG00-2BA0 |
For an overview and more information on all available firmware versions, see
The STARTER commissioning tool (V4.4 and higher) plus SSP supports the commissioning and maintenance of SIMATIC ET 200pro FC-2 frequency converters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.
Description | Article No. |
---|---|
STARTER commissioning tool 1) on DVD-ROM | 6SL3072-0AA00-0AG0 |
1) The STARTER commissioning tool is also available on the internet at
www./starter
The mini USB interface cable is used to control and commission a converter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool version 4.4 and higher, plus SSP) has been installed.
Description | Article No. |
---|---|
PC converter connection kit 2 Mini USB interface cable for communication with a PC, 3 m (9.84 ft) long | 6SL3255-0AA00-2CA0 |
Description | Article No. |
---|---|
Connecting cable pre-assembled at one end Power supply cable, open at one end, for Q4/2, angled, 4 × 4 mm2 |
|
1.5 m (4.92 ft) long | 3RK1911-0DB13 |
5 m (16.4 ft) long | 3RK1911-0DB33 |
Connector set for the power supply Q4/2 |
|
2.5 mm2 | 3RK1911-2BE50 |
4 mm2 | 3RK1911-2BE10 |
6 mm2 | 3RK1911-2BE30 |
Motor cables pre-assembled at one end for motors with brake and temperature sensor | Article No. (HTG: supplied by Harting) |
---|---|
Cross-section | 4 × 1.5 mm2 |
1.5 m (4.92 ft) long | HTG: 61 88 201 0288 |
ZKT: 70020501000150 | |
3 m (9.84 ft) long | HTG: 61 88 201 0289 |
ZKT: 70020501000300 | |
5 m (16.4 ft) long | HTG: 61 88 201 0290 |
ZKT: 70020501000500 | |
10 m (32.8 ft) long | HTG: 61 88 201 0299 |
ZKT: 70020501001000 | |
Connector set for motor cable Q8, shielded | HTG: 61 83 401 0131 |
ZKT: 10032001 |
The power jumper plug is used for 400 V power transmission to following 400 V modules.
Description | Article No. |
---|---|
Power jumper plugs | 3RK1922-2BQ00 |
Pulse frequency
Ambient temperature | Rated output current in A | ||||||
---|---|---|---|---|---|---|---|
°C | 4 kHz | 6 kHz | 8 kHz | 10 kHz | 12 kHz | 14 kHz | 16 kHz |
0 ... 55 (1.1 kW) | 3.5 | 2.8 | 2.2 | 1.6 | 1.1 | 0.5 | 0.0 |
0 ... 45 (1.5 kW) | 3.9 | 3.9 | 3.9 | 3.6 | 3.3 | 2.7 | 2.2 |
Rated output current as a function of the pulse frequency
Installation altitude
Permissible output current as a function of the installation altitude
Relationship between pulse frequency, temperature and output base-load current
Output current as a function of the pulse frequency and ambient temperature
6ES7288-3AT04-0AA0 6ES7288-3AT04-0AA0