门连锁旋转装置,完整
8UC71 62-6BD22 或 8UC71 72-8BD22 包括在旋转操作机构的交付范围内,整套交付,订货号 3VL9 300-3H.05
8UC7111-6BD15 门驱动 8UC7 手柄钛灰色, 掩蔽框浅灰色 用于断路器 3VL1,3VL2,3VL3 用于工作轴 6x 6mm 采用新颜色的新设计 |
8UC7121-8BD15 门驱动 8UC7 红色手柄, 掩蔽框黄色 用于断路器 3VL1,3VL2,3VL3 用于工作轴 6x 6mm |
8UC7314-6BD44 门驱动 8UC7 手柄钛灰色, 掩蔽框浅灰色 用于断路器 3VL7,3VL8 用于工作轴 12x 12mm |
4NC Current Transformers for Measuring Purposes |
Standards | EN 60044-1, VDE 0414-44-1 |
---|---|
Window-type current transformers | The conductor to be measured (busbar or cable) is passed through the window opening and creates the primary circuit of the window-type current transformer. |
Pin-wound transformers: An economical solution especially for small primary currents of 5 A to 75 A is achieved when the conductor to be measured is pin-wound several times. | |
Primary rated operational current Ipn | Current transformers can be continuously loaded with 1.3 times the primary rated current (Ipn). |
Rated secondary current Isn | |
1 A | Particularly suitable for longer measuring leads. Cable losses of only 4 % in contrast to 5 A current transformers. |
5 A | 5 A current transformers create 25 times the power losses on measuring leads as compared with 1 A current transformers. These stray losses result in higher power in the case of long cables. Only recommended for use with short measuring leads. |
Accuracy class | |
Class 1 | Operation measurement, internal metering |
Class 3 | Coarse measurement |
Rated power Pn | The rated power of transformers is specified in VA. The actual load rating should be similar to the rated power; a lower actual load rating (underburden) increases the overcurrent factor and measuring instruments may be damaged in case of a short-circuit, a higher actual load rating (overburden) has a negative effect on the accuracy. |
With a frequency of 60 Hz the rated power increases to 1.2 times. With 162/3 Hz the output power decreases to 1/3 of the rated power. | |
Maximum voltage for equipment Um | This is the rms value of the maximum voltage between the conductors of a network. For this voltage the insulation must be rated at normal operating conditions. |
4NC5 current transformers are suitable for 720 V. | |
Overcurrent limiting factor FS | The overcurrent limiting factor is expressed using the characters FS and a factor, e.g. FS5 or FS10. |
When a short-circuit current flows through the primary winding of a current transformer, the load on the measuring instruments connected to the current transformer is the lower the smaller the overcurrent limiting factor is. | |
Rated short-time thermal current Ith | The rated short-time thermal current Ith is the rms value of the primary current with a duration of one second, whose heat effect the current transformer can resist without being damaged in the event of a short-circuited secondary winding. |
Rated impulse current Idyn | The rated impulse current Idyn is the highest instantaneous value of the current after a short-circuit whose force the current transformer can resist without being damaged. |
The rated impulse current is specified as peak value. |
Pin-winding increases the primary current of the current transformer. Consequently, window-type current transformers can also be used for low primary currents.
Basic type | 4NC51 12 | 4NC51 13 | 4NC51 15 | 4NC51 17 | 4NC51 21 | 4NC51 22 | 4NC51 23 | ||
---|---|---|---|---|---|---|---|---|---|
Rated primary current | A | 50 | 60 | 75 | 100 | 150 | 200 | 250 | |
Service | VA | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 5 | 5 | |
Primary current to be measured | Number of required pin windings | ||||||||
A | Class 3 | Class 1 | |||||||
4NC51 used as pin-wound transformer | 5 | 10 | – | – | – | – | – | – | |
10 | 5 | 6 | – | 10 | – | – | – | ||
15 | – | 4 | 5 | – | 10 | – | – | ||
20 | – | 3 | – | 5 | – | 10 | – | ||
25 | 2 | – | 3 | 4 | 6 | 8 | 10 | ||
30 | – | 2 | – | – | 5 | – | – | ||
40 | – | – | – | – | – | 5 | – | ||
50 | – | – | – | 2 | 3 | 4 | 5 | ||
75 | – | – | – | – | 2 | – | – |