SIEMENS西门子模块6ES7141-3BH00-0XA0
SIEMENS西门子模块6ES7141-3BH00-0XA0
SIMATIC ET 200SP ECC charging controllers
SIPLUS and SIMATIC Electrical Charge Controller (SECC) are the key components in infrastructure solutions for the conductive charging of electric vehicles.
They perform the following functions:
Detection of the charging cable and its permissible current carrying capacity
Transfer of the maximum charging current from the charging station to the electric vehicle
Evaluation of the status **s from the electric vehicle:
Ready for charging
Charging
Charging with ventilation
Cost-optimized, space-saving charging infrastructure solutions due to compact design based on SIMATIC ET 200SP.
Control of charging outputs according to IEC 61851 by parameterizable SIMATIC ET 200SP TM ECC 2xPWM ST charging controller
Control of load tap-off
Control of connector lock
Evaluation of connector lock or load contactor status
The SIMATIC ET 200SP TM ECC PL ST charging controller fully controls a DC charging process according to DIN SPEC 70121.
The following sequences are performed:
Session Setup
Service Discovery
Service and Payment Selection
Contract Authentication
Charge Parameter Discovery
Power Delivery
Charging Status
Cable Check
Pre Charging
Current Demand
Welding Detection
Session Stop
Accessories: Calibration Kit TM ECC CCS2
Expansion kit for calibration of the power line ** strength of an EVSE.
According to DIN SPEC 70121 / ISO15118 or design guidelines for CCS charging stations Type 2
Suitable for the SIMATIC ET 200SP TM ECC PL ST technology module
Article number | 6FE1242-6TM10-0BB1 | 6AG1242-6TM10-2BB1 | 6FE1242-6TM20-0BB1 | |
---|---|---|---|---|
SIMATIC ET 200SP TM ECC 2xPWM ST | SIPLUS ET 200SP TM ECC 2xPWM ST | SIMATIC ET 200SP TM ECC PL ST | ||
General information |
|
|
| |
Product type designation | ECC 2x PWM ST | ECC PL ST | ||
HW functional status | 1 | 1 | ||
Firmware version | V1.04 | V1.1 | ||
● FW update possible | Yes | |||
Product description | Technology modules for the conductive AC charging of electric vehicles according to IEC 61851 | Communication controller for controlling conductive AC charging according to IEC 61851 | Technology module for the conductive charging of electric vehicles according to DIN 70121 | |
usable BaseUnits | BU type B0, B1 | |||
Color code for module-specific color identification plate | CC40 | |||
Number of channels | 2; Acc. to IEC 61851-1 Mode 3 and/or SAE J1772 | 2; According to IEC 61851/SAE J1772 | 1; Acc. to IEC 61851-1 Mode 4 and DIN SPEC 70121 | |
Product function |
|
|
| |
● I&M data | Yes; I&M0 to I&M3 | |||
● Isochronous mode | No | |||
Engineering with |
|
|
| |
● STEP 7 TIA Portal configurable/integrated from version | V14 SP1 | STEP 7 V16 or higher | ||
Installation type/mounting |
|
|
| |
Mounting type | standard rail | |||
Mounting position | Horizontal | Horizontal, vertical | ||
Supply voltage |
|
|
| |
Type of supply voltage | DC | |||
Rated value (DC) | 24 V | |||
permissible range, lower limit (DC) | 19.2 V | |||
permissible range, upper limit (DC) | 28.8 V | |||
Reverse polarity protection | Yes; against destruction | |||
Load voltage L+ |
|
|
| |
● Rated value (DC) | 24 V | 24 V | ||
● permissible range, lower limit (DC) | 19.2 V | |||
● permissible range, upper limit (DC) | 28.8 V | |||
● Reverse polarity protection | Yes | |||
Input current |
|
|
| |
Current consumption, typ. | 40 mA | |||
Current consumption, max. | 90 mA | 100 mA | ||
Digital inputs |
|
|
| |
Number of digital inputs | 2; 1 per channel | 0 | ||
Digital inputs, parameterizable | Yes; 12 V / 24 V | No | ||
Digital input functions, parameterizable |
|
|
| |
● Freely usable digital input | No; Readback contact contactor / connector lock | |||
Input voltage |
|
|
| |
● Type of input voltage | DC | |||
● for ** "0" | <0.2 V (nom) | |||
● for ** "1" | >0.6 V (nom) | |||
● permissible voltage at input, min. | 0 V | |||
● permissible voltage at input, max. | 30 V | |||
Cable length |
|
|
| |
● shielded, max. | 10 m | |||
● unshielded, max. | 30 m | |||
Digital outputs |
|
|
| |
Type of digital output | Transistor | |||
Number of digital outputs | 2; 1 per channel | 2; 1x digital out TRIP function as open collector, 1x digital out (DQ P) as open collector | ||
Current-sinking | Yes | |||
short-circuit proof | Yes | |||
Short-circuit protection | Yes; electronic/thermal | |||
Digital output functions, parameterizable |
|
|
| |
● PWM output | Yes; According to IEC 61851 | Yes; Acc. to DIN SPEC 70121 | ||
— Number, max. | 2; 1 per channel | 1; 1 per channel | ||
— Cycle duration, parameterizable | No; 1 kHz | |||
● Connection of a DC motor | Yes; ACT p/n connector locking | No; Only fixed charging cables are permitted for DC charging systems | ||
Switching capacity of the outputs |
|
|
| |
● with resistive load, max. | 1.3 A | 0.6 A; Per digital output | ||
Output voltage |
|
|
| |
● Type of output voltage | DC | |||
● Rated value (DC) | 24 V | |||
Cable length |
|
|
| |
● unshielded, max. | 30 m; when using a PROFIBUS line | 30 m | 10 m | |
Analog outputs |
|
|
| |
Number of analog outputs | 2; Control pilot acc. to IEC 61851-1 and/or SAE J1772 | 1 | ||
Type of analog output | Control pilot including Powerline Green Phy, acc. to DIN SPEC 70121 | |||
Connection of a DC motor | Yes; Motor for connector lock | No | ||
Protocols |
|
|
| |
Bus communication | Yes | Yes; Backplane bus | ||
Vehicle communication according to IEC 61851 | Yes; MODE 3 | Yes; Mode 4 | ||
Interrupts/diagnostics/status information |
|
|
| |
Alarms |
|
|
| |
● Diagnostic alarm | Yes | |||
Diagnoses |
|
|
| |
● Monitoring the supply voltage | No | No; Supply voltage diagnostics | ||
● Wire-break | No | |||
● Short-circuit | Yes | No | ||
Diagnostics indication LED |
|
|
| |
● ERROR LED | Yes; red LED | No | ||
● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | |||
● Channel status display | Yes; green LED | |||
● for module diagnostics | Yes; green/red DIAG LED | |||
Potential separation |
|
|
| |
Potential separation channels |
|
|
| |
● between the channels | No | No; Only one channel is available | ||
● between the channels and backplane bus | Yes | |||
Isolation |
|
|
| |
Isolation tested with | 707 V DC | |||
Degree of pollution | 2 | |||
EMC |
|
|
| |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge | |||
Field-related interference acc. to IEC 61000-4-3 | 10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) | |||
Conducted interference due to burst acc. to IEC 61000-4-4 | 2 kV ** lines | |||
Conducted interference due to surge acc. to IEC 61000-4-5 | On DC supply lines: 0.5 kV symmetrical and asymmetrical | |||
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | 10 V (0.15 ... 80 MHz) | |||
Degree and class of protection |
|
|
| |
IP degree of protection | IP20 | |||
Standards, approvals, certificates |
|
|
| |
Certificate of suitability | CE / RCM / EAC / UL / KC | CE | CE / RCM / EAC / UL / KC | |
Ambient conditions |
|
|
| |
Ambient temperature during operation |
|
|
| |
● min. | -30 °C | -30 °C | ||
● max. | 60 °C | 60 °C | ||
● horizontal installation, min. | -30 °C | -30 °C; = Tmin | -30 °C | |
● horizontal installation, max. | 60 °C | 60 °C; = Tmax | 60 °C | |
● vertical installation, min. | -30 °C | -30 °C; = Tmin | -30 °C | |
● vertical installation, max. | 50 °C | 50 °C; = Tmax | 50 °C | |
Ambient temperature during storage/transportation |
|
|
| |
● Storage, min. | -40 °C | |||
● Storage, max. | 70 °C | |||
● Transportation, min. | -40 °C | |||
● Transportation, max. | 70 °C | |||
Altitude during operation relating to sea level |
|
|
| |
● Installation altitude above sea level, max. | 2 000 m | 5 000 m | 2 000 m | |
● Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) | Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) | |
Relative humidity |
|
|
| |
● Operation, min. | 5 % | 5 % | ||
● Operation, max. | 95 %; no condensation | 95 %; no condensation | ||
● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |||
Vibrations |
|
|
| |
● Vibration resistance during operation acc. to IEC 60068-2-6 | 10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g | |||
Shock testing |
|
|
| |
● Shock resistance acc. to IEC 60068-2-27 | 15 g / 11 ms | |||
Resistance |
|
|
| |
Coolants and lubricants |
|
|
| |
— Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air | |||
Use in stationary industrial systems |
|
|
| |
— to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | |||
— to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |||
— to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | |||
— Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |||
Usage in industrial process technology |
|
|
| |
— Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | |||
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | |||
Remark |
|
|
| |
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | |||
Conformal coating |
|
|
| |
● Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability | |||
● Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection | |||
● Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life | |||
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A | |||
Decentralized operation |
|
|
| |
to SIMATIC S7-1500 | Yes | |||
Dimensions |
|
|
| |
Width | 20 mm | |||
Height | 73 mm | |||
Depth | 58 mm | |||
Weights |
|
|
| |
Weight, approx. | 32 g | 51 g | ||
Other |
|
|
| |
Note: | The Tone Mask of the Green Phy defined in DIN 70121 for North America applies |
SIEMENS西门子模块6ES7141-3BH00-0XA0