产品描述
西门子总线电缆6XV1830-OEH1O
西门子总线电缆6XV1830-OEH1O
SIMARIS planning tools for systems with SINAMICS drives
Electrical planning for power distribution in non-residential and industrial buildings has never been more complex. To ensure you, as a specialist planner, have the best hand when it comes to electrical planning with SINAMICS drives, we provide support with the following efficient software tools: SIMARIS design for dimensioning and SIMARIS project for calculating the space requirements of the distribution boards.
Supported SINAMICS drives:
SINAMICS G120, SINAMICS G120D, SINAMICS G120X
SINAMICS G115D
SINAMICS G130, SINAMICS G150
SIMARIS design is a planning tool for quick and effective network calculation and dimensioning of power distribution for non-residential and industrial buildings.
Starting in the planning phase, the entire electrical circuit required for the project can be structured and dimensioned on the basis of real products. For this purpose, the network structure is initially set up based on the stored modules for infeeds, couplings, distributors and branch circuits. It is also possible to reuse stored favorites, such as those processed for previous similar projects. Suitable components and distribution systems are then automatically selected from the product database stored in SIMARIS design based on the selected project-specific parameters and technical data. This precludes the extra costs so often incurred in the implementation phase as a result of systems that have not been correctly coordinated.
Any configuration of electric power distribution is subject to frequent change and adaptation, not only in the planning phase, but also in the implementation phase. SIMARIS design makes it easy to incorporate such changes in the supply concept and to automatically check their reliability in terms of sound engineering practice and the currently applicable standards.
SIMARIS design professional, a program version available for a fee, offers additional useful functions. It can be used to carry out and also document selectivity analyses, essential for safety power supply systems. There is also the option of analyzing and optimizing the energy efficiency of the planned network.
The versatile output variants enable precise documentation of the project structure and of the calculated data suitable for every phase of a project.
There is also the option of exporting the project data. This enables further processing of the planned project in SIMARIS project, and thus also supports and facilitates system planning.
Reduction in processing overhead for projects
Dimensioning of electrical networks on the basis of real products according to sound engineering practice and the currently applicable standards (VDE, IEC)
Automatic selection of the correct components from medium voltage through to interfacing of the load from the stored product database, i.e. no detailed knowledge of products and systems required
Open definition of the types of mains operation and switching states
Calculation of the short circuit current, load flow, voltage drop and energy balance
Incorporation of the required person, short circuit and overload protection
Option of factoring in any necessary functional endurance
Display and dimensioning of cable and busbar trunking systems for power conveyance and distribution
High planning reliability coupled with flexibility in the planning and implementation process
Tracking changes via Change index possible
Simple adaptation in the case of application changes or expansions
Option for saving frequently required modules in the Favorites library
Output of the created network diagram, as well as detailed parts lists and data lists
Incorporation of country-specific product portfolios
Comprehensive documentation of planning results with simple data transfer (Office, CAD etc.)
SIMARIS design is a software tool for the network calculation and dimensioning of power distribution for non-residential and industrial buildings. Whether for a shopping center, a hospital or production facilities - with SIMARIS design you can reduce the overhead required for the overall planning of power distribution systems and hence the time spent on the selection and dimensioning of equipment.
SINAMICS Startdrive commissioning tool
SINAMICS Startdrive is integrated in the TIA Portal and is a tool for the configuration, commissioning and diagnostics of the SINAMICS family of converters.
The SINAMICS Startdrive commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives. Time-saving and guided step-by-step commissioning with maximum flexibility is complemented by user-friendly graphic function views for all drive functions, including functional safety (Safety Integrated) and drive-based technology functions (e.g. EPos). The automatic message display, the powerful real-time trace and the context-sensitive online help make converter diagnostics very easy.
The software packages based on the TIA Portal are harmonized with each other and offer important benefits, the main advantage being a shared project storage. The TIA Portal enables simple integration of SINAMICS converters in your automation solution. Thanks to the standardization of operator actions and the integration in general TIA Portal operating concepts (e.g. UMAC, Openness) as well as standard TIA Portal functions (e.g. Undo/Redo), familiarization is easy both for drive experts as well as SIMATIC users. Special focus is placed on the interaction between SIMATIC and SINAMICS, especially when connecting the SINAMICS drives to SIMATIC technology objects.
SINAMICS Startdrive Basic enables complete commissioning, diagnostics, parameterization, optimization and connection to the PLC for the following SINAMICS converters integrated in SINAMICS Startdrive:
SINAMICS G120, G120C, G120D, G120P
SINAMICS G115D
SINAMICS G130, G150
SINAMICS S120 *), S150
SINAMICS S210
SINAMICS MV
*) Including SINAMICS S220 Smart Line Modules in booksize format as of SINAMICS Startdrive V17 Update 1.
With SINAMICS Startdrive Advanced (available as of V15) you benefit from powerful engineering functions that save you considerable time and ultimately costs.
Advanced functions for SINAMICS Startdrive: Safety acceptance test for SINAMICS G120, SINAMICS S120 and SINAMICS S210
Safety Activation Test
Improved optimization options in the drive for CU320‑2 PN/DP and CU310‑2 PN-based drive units: Extended measuring functions (available as of V5.2 SP3)
Prompted acceptance test wizard for all drive-based Safety Integrated functions (Basic and Extended Safety)
Automatic and safety function-specific generation of traces to analyze the machine behavior
Generation of an acceptance report as Excel file (xlsx format, can also be used with OpenOffice)
Available for SINAMICS G120, G120C, G115D, G120D, G120P, S120 and S210
Also contains all Startdrive Basic functions
License key only required, no additional installation
Startdrive Basic V17
Extension for UMAC: Additional function right for drive parameter changes including DCC
Extension of the SINAMICS S210 family: Support of the SINAMICS firmware V5.2 SP3
Extension of the SINAMICS S120 family: Support of CU320-2 DP (in V4.8 or higher) for SINAMICS S120 Booksize and Chassis
Extension of the SINAMICS MV family: Support of the SINAMICS firmware V5.2 SP2
Extensions for CU320‑2 PN/DP and CU310‑2 PN-based drive units
Support of the SINAMICS firmware V5.2 SP3
User-defined parameter list
Data set switchover (drive, motor, encoder and command data sets)
Improved optimization option in the drive (Bode diagram)
Extensions for CU320‑2 Integrated in SIMATIC Drive Controller
EPOS (basic positioner)
DCC (Drive Control Chart)
Improved interaction between drives and SIMATIC technology objects
Transfer of optimization parameters from One Button Tuning (OBT) of the drive to the technology object
Display of drive configuration status in the technology object
Support of new SINAMICS Technology Extensions (TEC) function, see
Extension of the SINAMICS G120 family:
Support of the SINAMICS G115D distributed drive
Improved AS‑i connection for SINAMICS G115D AS‑i (in combination with SIMATIC ET200SP AS‑i Master)
Extension of technology object "BasicPosControl"
Physical units
Entry of mechanical data
Extension of Openness for drive units
Support of the SINAMICS G115D distributed drive
More information on Startdrive Openness can be found at
Startdrive Advanced V17
Extension of safety acceptance test
Safety Activation Test
Support of the SINAMICS G115D distributed drive
Expansion for CU320‑2 PN/DP and CU310‑2 PN-based drive units: Improved optimization options in the drive: Extended measuring functions (available as of V5.2 SP3)
SINAMICS Startdrive can be installed as an optional package to SIMATIC STEP 7 or as a stand-alone application (without SIMATIC STEP 7).
The following table shows the recommended hardware and system equipment for the operation of SINAMICS Startdrive.
Hardware | Recommendation |
---|---|
Computer | As of SIMATIC FIELD PG M5 Advanced (or comparable PC) |
Processor | Intel Core i5-8400H (2.5 ... 4.2 GHz; 4 cores + hyper-threading; 8 MB Smart Cache) |
RAM | 16 GB or more (32 GB for large projects) |
Hard disk | SSD with at least 50 GB available memory |
Screen resolution | 15.6" Full HD display (1920 × 1080 or larger) |
Operating systems | Microsoft Windows 10 (64 bit) Windows 10 Professional Version 1909, 2004, 2009/20H2 Windows 10 Enterprise 1909, 2004, 2009/20H2 Windows 10 IoT Enterprise 2016 LTSB Windows 10 IoT Enterprise 2019 LTSC Windows 10 Professional Version 1909, 2004, 2009/20H2 Windows 10 Enterprise 1909, 2004, 2009/20H2 Windows 10 IoT Enterprise 2016 LTSB Windows 10 IoT Enterprise 2019 LTSC |
SINAMICS Startdrive V17 operates with STEP 7, WinCC and Scout TIA V17 in one framework
SINAMICS Startdrive V17 can be installed on the same computer as other versions of SINAMICS Startdrive V12 to V16
SINAMICS Startdrive can be installed on the same computer as SINAMICS MICROMASTER STARTER
SINAMICS Startdrive can be installed in a virtual machine. For this purpose, one of the following virtualization platforms in the specified version or a newer version can be used:
Microsoft Windows 10 Professional Version 1909, 2004, 2009/20H2
Microsoft Windows 10 Enterprise 1909, 2004, 2009/20H2
Microsoft Windows 10 IoT Enterprise 2016 LTSB
Microsoft Windows 10 IoT Enterprise 2019 LTSC
The following safety programs have been tested with SINAMICS Startdrive V17:
Virus scanners:
Symantec Endpoint Protection 14.2
Trend Micro OfficeScan 12.0
McAfee Endpoint Security (ENS) 10.6
Kaspersky Endpoint Security 11.3
Microsoft Defender
Qihoo 360 "Safe rd 12.1" + "Virus Scanner"
Encryption software:
Microsoft Bitlocker
Host-based Intrusion Detection System
McAfee Application Control 8.2
您是第268929位访客
版权所有 ©2024 八方资源网 粤ICP备10089450号-8
浔之漫智控技术(上海)有限公司 保留所有权利.
浔之漫智控技术(上海)有限公司 保留所有权利.
技术支持: 八方资源网 八方供应信息 投诉举报 网站地图手机网站
微信号码
地址:上海市 松江区 小昆山镇 荡湾村 广富林4588弄52号3楼
联系人:颜经理女士
微信帐号:X15021292620