Line reactor for PM240-2 Power Modules, frame size FSA

Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter.

集成

A DC link reactor is integrated in the PM240‑2 Power Modules, frame sizes FSD to FSF, and therefore no line reactor is required.

Line reactors that are optionally available depending on the Power Module used

 

Frame size

 

FSA

FSB

FSC

FSD

FSE

FSF

PM240‑2 Power Module with integrated braking chopper

Line-side components

Line reactor (only for 3 AC versions)

S

S

S

I

I

I



S = Lateral mounting

I = Integrated

技术规范

Line voltage 200 ... 240 V 3 AC or 380 ... 480 V 3 AC

Line reactor

6SL3203-0CE13-2AA0

6SL3203-0CE21-0AA0

6SL3203-0CE21-8AA0

6SL3203-0CE23-8AA0

Rated current

A

4

11.3

22.3

47

Power loss

at 50/60 Hz

W

23/26

36/40

53/59

88/97

Line supply/load connection

1L1, 1L2, 1L3
2L1, 2L2, 2L3

 

Screw terminals

Screw terminals

Screw terminals

Screw terminals

Conductor cross-section

mm2

4

4

10

16

PE connection

 

M4 × 8; U washer; spring lock washer

M4 × 8; U washer; spring lock washer

M5 × 10; U washer; spring lock washer

M5 × 10; U washer; spring lock washer

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

Width

mm (in)

125 (4.92)

125 (4.92)

125 (4.92)

190 (7.48)

Height

mm (in)

120 (4.72)

140 (5.51)

145 (5.71)

220 (8.66)

Depth

mm (in)

71 (2.80)

71 (2.80)

91 (3.58)

91 (3.58)

Weight, approx.

kg (lb)

1.1 (2.43)

2.1 (4.63)

2.95 (6.50)

7.8 (17.2)

Suitable for
PM240-2 Power Module standard variant
200 ... 240 V 3 AC

Type

6SL3210-1PB13-0 . L0
6SL3210-1PB13-8 . L0

6SL3210-1PB15-5 . L0
6SL3210-1PB17-4 . L0
6SL3210-1PB21-0 . L0

6SL3210-1PB21-4 . L0
6SL3210-1PB21-8 . L0

Frame size

 

FSA

FSB

FSC

Suitable for
PM240-2 Power Module standard variant
380 ... 480 V 3 AC

Type

6SL3210-1PE11-8 . L1
6SL3210-1PE12-3 . L1
6SL3210-1PE13-2 . L1

6SL3210-1PE14-3 . L1
6SL3210-1PE16-1 . L1
6SL3210-1PE18-0 . L1

6SL3210-1PE21-1 . L0
6SL3210-1PE21-4 . L0
6SL3210-1PE21-8 . L0

6SL3210-1PE22-7 . L0
6SL3210-1PE23-3 . L0

Frame size

 

FSA

FSA

FSB

FSC

Suitable for
PM240-2 Power Module push-through variant
200 ... 240 V 3 AC

Type

6SL3211-1PB13-8 . L0

6SL3211-1PB21-0 . L0

6SL3211-1PB21-8 . L0

Frame size

 

FSA

FSB

FSC

Suitable for
PM240-2 Power Module push-through variant
380 ... 480 V 3 AC

Type

6SL3211-1PE18-0 . L1

6SL3211-1PE21-8 . L0

6SL3211-1PE23-3 . L0

Frame size

 

FSA

FSB

FSC

Line filter for PM240-2 Power Modules

With one of the additional line filters, the Power Module attains a higher radio interference class.

集成

Line filters that are optionally available depending on the Power Module used

 

Frame size

 

FSA

FSB

FSC

FSD

FSE

FSF

PM240‑2 Power Module with integrated braking chopper

Line-side components

Line filter class A according to EN 55011

F

F

F

F 2)

F 2)

F 2)

Line filter class B according to EN 55011
(only for 400 V versions)

U 1)

U 1)

U 1)



F = Power Modules available with and without integrated filter class A

U = Base component

– = Not possible

1) Lateral mounting is the only possible option for push-through variants.

2) PM240‑2 200 V versions, frame sizes FSD to FSF are only available without integrated line filter.

技术规范

Line voltage 380 ... 480 V 3 AC

Line filter class B

 

6SL3203-0BE17-7BA0

6SL3203-0BE21-8BA0

6SL3203-0BE23-8BA0

Rated current

A

11.4

23.5

49.4

Pulse frequency

kHz

4 ... 16

4 ... 16

4 ... 16

Line supply connection

L1, L2, L3

 

Screw terminals

Screw terminals

Screw terminals

Conductor cross-section

mm2

1 ... 2.5

2.5 ... 6

6 ... 16

Load connection

U, V, W

 

Shielded cable

Shielded cable

Shielded cable

Cable cross-section

mm2

1.5

4

10

Length

m (ft)

0.45 (1.48)

0.5 (1.64)

0.54 (1.77)

PE connection

 

On housing via M5 screw stud

On housing via M5 screw stud

On housing via M6 screw studs

Conductor cross-section

mm2

1 ... 2.5

2.5 ... 6

6 ... 16

Degree of protection

 

IP20

IP20

IP20

Dimensions

 

 

 

 

Width

mm (in)

73 (2.87)

100 (3.94)

140 (5.51)

Height

mm (in)

202 (7.95)

297 (11.69)

359 (14.13)

Depth

mm (in)

65 (2.56)

85 (3.35)

95 (3.74)

Possible as base component

 

Yes

Yes

Yes

Weight, approx.

kg (lb)

1.75 (3.86)

4 (8.82)

7.3 (16.1)

Suitable for
PM240‑2 Power Module
standard variant
380 ... 480 V 3 AC

Type

6SL3210-1PE11-8UL1
6SL3210-1PE12-3UL1
6SL3210-1PE13-2UL1
6SL3210-1PE14-3UL1
6SL3210-1PE16-1UL1
6SL3210-1PE18-0UL1

6SL3210-1PE21-1UL0
6SL3210-1PE21-4UL0
6SL3210-1PE21-8UL0

6SL3210-1PE22-7UL0
6SL3210-1PE23-3UL0

Suitable for
PM240‑2 Power Module
push-through variant
380 ... 480 V 3 AC
(lateral mounting only)

Type

6SL3211-1PE18-0UL1

6SL3211-1PE21-8UL0

6SL3211-1PE23-3UL0

Frame size

 

FSA

FSB

FSC



http://yan6789.b2b168.com
产品推荐

Development, design, production and sales in one of the manufacturing enterprises

您是第265230位访客
版权所有 ©2024 八方资源网 粤ICP备10089450号-8 浔之漫智控技术(上海)有限公司 保留所有权利.

浔之漫智控技术(上海)有限公司 保留所有权利.

技术支持: 八方资源网 八方供应信息 投诉举报 网站地图