西门子SM1221开关量模块
  • 西门子SM1221开关量模块
  • 西门子SM1221开关量模块

产品描述

货期 安装方式现场安装 LD指令处理器硬PLC I/O点数128 功能控制逻辑模组 工作电压120/380V 输出频率45Hz 处理速度0.02μs 数据容量1000 产品认证CE 环境温度40℃ 环境湿度80℃ 重量0.2kg 销售范围全国 质保日期质保一年 西门子产品系列自动化设备全系列 产品询价随时 产品包装全新 加工定制

西门子SM1221开关量模块

西门子SM1221开关量模块


As a simple fieldbus protocol, USS (Universal Serial Interface protocol of Siemens AG, 1992) can be used both cyclically and acyclically. Based on RS485 physical bus characteristics, up to 32 nodes can be networked to one bus segment and connected to a higher-level controller. This protocol is generally used when there are limited demands on data throughput.


Ethernet Industrial Protocol (EtherNet/IP) is an open standard for industrial networks. EtherNet/IP is used to transmit cyclic I/O data and acyclic parameter data. EtherNet/IP was developed by the ODVA (Open DeviceNet Vendor Association) and belongs to the international standard series IEC 61158.

CANopen is a communication protocol based on CAN physical characteristics, which is predominantly used in the automation industry and for networking within complex devices. Originally conceived as a fieldbus for networking devices in motion control applications such as handling systems, CANopen has since established itself in the field of medical engineering, vehicle automation, rail and ship networking as well as building automation. Interoperability of CANopen is ensured through the use of application and device profiles, whereby the wide range of options offered by the bus specification enables an appropriate, precise selection to be made for the application or device in question. Furthermore, converters with CANopen support the "CiA 402 Electrical Drives" device profile.

The major part of the functionality of SINAMICS drives is implemented in software. This "embedded" software delivers the function of the product and is therefore a significant component of the overall product. The embedded software is also known as firmware, because it is firmly connected to specific hardware.

In the case of SINAMICS drives, the firmware is subdivided into the operating system (OS) with drivers for the hardware and the converter functions, which are also referred to as the runtime (RT) functions.

Introduction

The available firmware functions are so extensive that the overall functional scope has been structured into function groups corresponding to their main applications.

The 8 main groups are:


Basic Drive Functions

Standard Technology Functions

Advanced Technology Functions

Communication Functions

Safety Integrated Functions

Energy Efficiency Functions

Common Engineering

Applications & Branch know-how


Functionality, including technology and configuration

Basic Drive Functions

The main groups, especially the "Basic Drive Functions", are divided up into further subgroups.


Control modes

Availability

Setpoints and commands

Limiters, timers and monitoring functions

Diagnostics

Protection


Basic Drive Functions - Control Functions

Control modes

The control methods are the core of the entire converter firmware. They are responsible for optimum movement of the connected motor and the attached machines. The better the control functions, the faster, better and more smoothly the machine operates, thereby significantly enhancing the quality of the production output.

A distinction is made between the following methods:


V/f control (open-loop control)

Vector control (closed-loop control)

Servo control (closed-loop control)


Further classification refers to the control variables:


Current control

Speed control

Torque control

Position control

Technological process control (pressure, flow rate, temperature, fill level, etc.)


Availability

Availability refers to the frequency ratio, namely how often or seldom a single device restricts the entire production process due to a problem. That is why it is important in terms of availability that a drive enters the faulty state only when it is essential for self-protection. Moreover, it is important that the cause of the pending problem is identified and eliminated as quickly as possible.

Features and measures to increase availability:


Parallel connections, for example, to maintain emergency operation (possibly also at a lower rating), if a power unit fails

Automatic restart

Flying restart

Vdc control with kinetic buffering

Redundancy (hardware, communication, etc.)


Setpoints and commands

The setpoint channel is the link between the setpoint source and the motor control. The converter has a special feature that supports ltaneous input of two setpoints. Generation and subsequent modification of the total setpoint (influencing the direction, skip frequency, up/down ramp) take place in the setpoint channel.

Different sources of command usually result from the requirements to operate a drive from different places (on-site/remote), in different situations (standard/emergency mode) and/or different operating. The BICO binector connector technology allows SINAMICS to configure and combine the command and setpoint sources completely individually.

The following can be used for switching:


Dataset switchover

Switching elements among the Free Function Blocks (FFB)

Fixed values


Limiters and monitoring functions

Limiters or limits are used to constrain input and/or output variables as appropriate to the connected machine; this means that not all positioning variables are used over their full range but are limited judiciously to enhance the safety and quality of the production process.

Timers/runtime counters are used to obtain information or make statements about the temporal course of a process.


Recording application information for manufacturers

Recording operating times for users

Configurable timers for monitoring intervals

Configurable timers for triggering activities at certain intervals (e.g. maintenance work)


Monitoring is used for early detection of conditions that may be detrimental or even dangerous to the connected machine, so that they can be counteracted expediently. If an appropriate countermeasure is not initiated, a protective response of the converter with probable fault shutdown will ultimately result.

Diagnostics

The "Diagnostics" subgroup comprises all those functions that provide assistance with determining the possible causes of a problem.
If problems occur in a process, or in the driven machine, further interpretation of the measured variables in the converter is required. To this end, different **s should be correlated with respect to time and then observed.

This includes:


Error and alarm buffer

Diagnostic buffer

List of missing **s that interrupt operation

Tracing for temporal assignment of ** profiles

I/O lation

Telegram content diagnoses

Terminal status


Protection

All protection functions counteract any possible damage to the converter and/or motor. This is why the shutdown thresholds cannot be parameterized but are factory-tuned and permanently set to match the built-in components. Alarm thresholds may be parameterized as a relative variable for shutdown threshold of some monitoring processes. Thus, a countermeasure that is sensitive to the process may still be initiated upon occurrence of the alarm.

Apart from protection of the hardware, protection of the parameterization and therefore protection of the intellectual expertise of the customer from unauthorized access and copying is also an important part of the protection functions.


Write protection

Know-how protection

Copy protection


Standard Technology Functions

The Standard Technology Functions are not restricted to a specific SINAMICS product family, but they are available in full or at least partially in SINAMICS S120 as well as in SINAMICS G120.


BICO technology

Free function blocks (FFB)

Basic positioner (EPos)

Technology controller (PID)


Standard Technology Functions

The Standard Technology Functions significantly expand the application spectrum of the SINAMICS drives because the functions are not permanently and unalterably interconnected; rather, they are interrupted at defined access points and can be connected or wired differently. The BICO technology makes it possible.

The FFBs enable additional, freely interpretable adaptations of the binary and analog ** flow to the given machine application. However, the FFBs are limited in terms of the absolute quantity and the computing intervals (sampling times) that can be selected. These blocks are NOT multi-instance capable.

With Epos, comprehensive positioning tasks are autonomous in SINAMICS (i.e. their solution does not need a higher-level control). And moreover, this integrated functionality is also extremely flexible: It can be used for highly dynamic servo control as well as for simple applications with vector-controlled asynchronous motors. Up to 64 target positions, as well as the respective traversing speeds, can be permanently stored in the drive during commissioning. Axes can be positioned either absolutely or relatively.
It is, however, also possible to transfer these parameters as required from a higher-level controller. This means that target positions and velocities can even be changed on-the-fly during a positioning run.

The technology controller (PID controller) permits all types of simple process controls to be implemented. It can be used, for example, to control the line pressure, fill level, temperature, flow or also tension control or load balancing.

For more information, see section Technology functions.

Advanced Technology Functions

The Advanced Technology Functions are the clear differentiating feature between the SINAMICS product families of SINAMICS G120 with the CU2xx‑2 Control Units and SINAMICS S120 with the CU3x0‑2 Control Units. The Advanced Technology Functions are only available for SINAMICS S120:


SINAMICS Technology Extensions (TEC)

SINAMICS Drive Control Chart (DCC)


Advanced Technology Functions

The Advanced Technology Functions are characterized by maximum flexibility and performance whereby extremely individual and, at the same time, efficient solutions can be achieved.

SINAMICS DCC comprises the block library, so-called DCB Drive Control Blocks and the DCC Editor for graphical interconnection of blocks. SINAMICS DCC is primarily employed to solve arithmetic and control-related tasks or logic functions associated with complex applications.

In addition to the DCB Standard library, the DCB Extension library can also be used to create applications.
The DCB Extension library is comprised of freely programmable blocks which are created for specific applications using DCB Studio and are then graphically interconnected with the DCC Editor in a similar fashion to standard blocks.

SINAMICS Technology Extensions (TECs) are configurable firmware expansions that are specifically created for use in a customized application with special requirements. This functionality can therefore be subsequently installed as an add-on to the standard scope of firmware functions. One example of a SINAMICS TEC is the VIBX vibration extinction for storage and retrieval systems.

For more information, see section Technology functions.

The functional scope of Advanced Technology Functions is scalable and flexible. Depending on the task, you can choose between configurable solutions provided by Siemens or freely created proprietary solutions in the drive.

Depending on the technology function, a license may be required for the application (see section Control Units and memory cards).

Safety Integrated Functions

See section Safety Integrated

Communication Functions

See section Communication

Energy Efficiency Functions

See section Energy efficiency

Common Engineering

All functions of the converters are implemented to enable a common engineering approach to their handling no matter which type of drive is selected; i.e. if a function is used in drive x, it can be configured intuitively and commissioned in the same way in drive y. Knowledge gained can therefore be reused easily and efficiently. The engineering and commissioning tools in particular such as SIZER for Siemens Drives (integrated in the TIA Selection Tool), STARTER and SINAMICS Startdrive reflect this approach.

For more information, see section Engineering tools.

Applications & Branch know-how

Siemens has applied these technology functions (standard and/or advanced) to generate numerous application solutions.
These applications can be downloaded from the Siemens Application Support website at 
//www./sinamics-applications

The STARTER and SINAMICS Startdrive commissioning tools can then be used to activate and configure the applications and download them to the Control Units.

Applications & Branch know-how

Depending on the technology function, a license may be required for the application (see section Control Units and memory cards).

In some branch-specific Control Units (e.g. CU230P‑2) branch-specific functions are also an integral part of the firmware.

For more information, see section Drive applications.




http://yan6789.b2b168.com
产品推荐

Development, design, production and sales in one of the manufacturing enterprises

您是第285575位访客
版权所有 ©2024 八方资源网 粤ICP备10089450号-8 浔之漫智控技术(上海)有限公司 保留所有权利.

浔之漫智控技术(上海)有限公司 保留所有权利.

技术支持: 八方资源网 八方供应信息 投诉举报 网站地图