西门子S7-1200继电器模块CPU1211C
西门子S7-1200CPU模块
The SINAMICS G115D distributed drive system provides fully preconfigured and ready-to-connect solutions in a modular concept that includes the converter, motor and gearbox.
The converter supports SIMOGEAR 2KJ8 geared motors with three-phase asynchronous motors with efficiency class IE3 or high-efficiency synchronous reluctance motors with efficiency class IE4.
It meets all requirements for horizontal conveyor system applications – from simple speed control to sophisticated encoderless vector control. Integrated functions such as fast/slow speed switchover, Quick Stop and limit position disconnector make the SINAMICS G115D particularly suitable for applications in conveyor systems.
For applications that require safety technology, the SINAMICS G115D offers the integrated STO (Safe Torque Off) function, which can be implemented without additional external components.
The SINAMICS G115D distributed drive system is available wall-mounted and motor-mounted.
Example: SINAMICS G115D distributed drive system, wall-mounted, PROFINET, version with plug-in connection, FSA, 1.5 kW
The wall-mounted converter with its different versions (frame sizes FSA to FSC) in a performance range from 0.37 kW to 7.5 kW is suitable for a large number of different applications. Thanks to the compact design with degree of protection IP65 (plug-in connection) or IP66 (cable gland), it can be seamlessly integrated into the system.
Example: SINAMICS G115D distributed drive system, motor-mounted, PROFINET, version with cable gland, FSA, 1.5 kW, SIMOGEAR motor LE 90, gearbox B49, hollow shaft
Example: SINAMICS G115D distributed drive system, motor-mounted, PROFINET, version with plug-in connection, FSA, 1.5 kW, SIMOGEAR motor LE 90, gearbox B49, hollow shaft
The motor-mounted converter with its different versions (frame sizes FSA and FSB) in a performance range from 0.37 kW to 4 kW is suitable for a large number of different applications. Thanks to its compact design with degree of protection up to IP65, it can be seamlessly integrated into the system.
Integration via PROFINET communication with PROFIsafe, AS-Interface, EtherNet/IP into a higher-level control system is very easy thanks to full TIA Portal integration, which provides a tool as well as an operating and data management concept. In addition, an optional web server module is available with the web server module SINAMICS G120 Smart Access (SAM) – a WLAN-based web server solution for simple and fast wireless setup with smartphones, tablets, or laptops during commissioning and for diagnostics.
The SINAMICS G115D distributed drive system is ready for digitalization. All operating data can be transferred to the MindSphere cloud solution. The MindSphere application "Analyze MyDrives" facilitates the process evaluation of operating data, with the possibility of adaptation to individual customer requirements. This simplifies the recording and evaluation of the operating conditions of the drive system.
User-friendly modular solution – pre-configured and ready for connection
Versatile, robust and reliable system
New design for quick and easy installation, cabling and commissioning
The wall-mounted and motor-mounted variants use the same platform
No control cabinet required, thanks to the installation on the machine less space required and lower cooling requirements
Long cables between the converters and the motors can be avoided (thus less power loss, reduced interference emissions, and lower costs for shielded cables and additional filters)
Supports SIMOGEAR 2KJ8 geared motors with asynchronous motors and high-efficiency synchronous reluctance motors according to efficiency class IE4
Worldwide use of the SIMOGEAR 2KJ8 geared motors independent of the line voltage
Temperature range from -30 °C to 55 °C (suitable for installation in deep-freeze applications)
Integrated safety, STO (Safe Torque Off) via fail-safe digital input F-DI or PROFIsafe
Perfectly prepared for digitalization thanks to various communication interfaces and integration of the AMD (Analyze MyDrives) application into the cloud solution MindSphere
Special properties for the intralogistics market (e.g. repair switches, local remote control, Safety Integrated, conveyor technology functions)
Siemens offers an innovative portfolio of frequency converters for optimal implementation in distributed drive solutions. The strengths of the individual members of the converter family allow easy adaptation to the most diverse application requirements:
Identical connection systems
User-friendly commissioning and configuration tools
Products from the family of distributed drives:
SINAMICS G115D distributed drive system (wall and motor-mounted)
SINAMICS G120D frequency converters
SIMATIC ET 200pro FC-2 frequency converters
SIRIUS M200D motor starters
The SINAMICS G115D distributed drive system is available as a wall-mounted and motor-mounted version, with degree of protection IP65/66.
The performance range for the wall-mounted version, for ranges from 0.37 kW to 7.5 kW and in the motor-mounted version, for ranges from 0.37 kW to 4 kW.
The converter is configurable regarding fieldbus communication (without, AS-Interface or PROFINET / EtherNet/IP) and connection method (cable gland or plug-in connection). Furthermore, the wall-mounted version can be configured with a repair switch, local remote control and the control voltage of the motor holding brake.
State-of-the-art IGBT technology with pulse width modulation (PWM) is used for extremely reliable and flexible motor operation. The closed-loop control electronics control and monitor the power electronics and the connected motor in several different control modes that can be selected.
The sensors of the conveyor element can be connected to the digital inputs of the converter. These **s can be transmitted to the higher-level control for further processing via PROFINET, EtherNet/IP or AS-Interface.
The SINAMICS G115D distributed drive systems are already equipped with the Safety Integrated Function STO (Safe Torque Off), with certification according to IEC 61508 SIL 2 as well as EN ISO 13849-1 PL d and Category 3. This can be activated either via the PROFIsafe communication protocol or via the fail-safe digital input F-DI.
The Siemens Product Configurator helps you configure the optimum drive technology products for a number of applications – starting with gearboxes, motors, converters as well as the associated options and components and ending with controllers, software licenses and connection systems.
The Siemens Product Configurator can be used on the internet without requiring any installation. The Siemens Product Configurator can be found in the Siemens Industry Mall at the following address:
www./spc
SINAMICS Startdrive is a tool integrated into the TIA Portal for configuring, commissioning and diagnostics of the SINAMICS converter family. SINAMICS Startdrive (V16 update 4 and higher) can be used to implement converter tasks with most of the SINAMICS G and SINAMICS S converter series. The commissioning tool has been optimized in terms of simplicity, ease of use, and consistent use of the benefits of the TIA Portal to provide a uniform working environment for PLC, HMI and drives.
The SINAMICS Startdrive Basic commissioning tool is available for free on the internet at
www./startdrive
The SINAMICS G115D distributed drive system is easily configured with the TIA Selection Tool under the drive dimensioning plug-in. It provides support when selecting the hardware and firmware components necessary to implement a drive task. The plug-in encompasses the configuration of the entire drive system and allows the handling of individual drives.
Intuitive user interface, menu-based operation and help
Configuration of the SINAMICS G115D distributed drive system
Adjustable load cycles and various mechanical systems integrated
Interface to the TIA Portal and Industry Mall
The TIA Selection Tool is available for free on the internet at
www./tia-selection-tool-standalone
Electrical planning: Even easier with software!
Electrical planning for power distribution in non-residential and industrial buildings has never been more complex. To ensure you, as a specialist planner, have the best hand when it comes to electrical planning with SINAMICS drives, we provide support with the following efficient software tools:
SIMARIS design for dimensioning
SIMARIS project for calculating the space requirements of the distribution boards
For SINAMICS G115D, Siemens offers an optional extension of warranty up to 2½ years via Service Protect:
Free for the first 6 months after registering the product at:
//myregistration.
With costs for 1 or 2 additional years for wall-mounted and motor-mounted versions
(complete system with converter and geared motor)
More information is available at:
Concerning standard warranty please ask your partner at Siemens. Your partner can be found in our Personal Contacts Database at:
www./automation-contact
Compact Operating Instructions are supplied in hard copy form in German, English and Chinese with every SINAMICS G115D.
To select the helical geared motor, parallel shaft geared motor, bevel geared motor and helical worm geared motor, see "Gearbox selection" or "Dimensional drawings" in the Industry Mall at:
www./sinamics-g115d/gear-selection-wall-mounted
or
www./sinamics-g115d/gear-selection-motor-mounted
The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions) as well as further technical specifications are available on the internet at:
www./sinamics-g115d/documentation
and in the Siemens Product Configurator
www./sinamics-g115d/configuration
SINAMICS G115D distributed converters, wall-mounted · 380 ... 480 V 3 AC | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated power 1) | Rated output current IN2) | Rated input current 3) | Frame size | SINAMICS G115D, wall-mounted | |||||||||||||
400 V | 480 V | at 400 V | at 400 V | | Data position in Article No. | ||||||||||||
kW | hp | A | A |
| 123456 | 7 | - | 8 | 9 | 10 | 11 | 12 | - | 13 | 14 | 15 | 16 |
380 ... 480 V 3 AC · Rated pulse frequency 4 kHz · Input frequency 45 ... 66 Hz | |||||||||||||||||
0.37 | 0.5 | 1.3 | 1.23 | FSA | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 0 | - | 3 | A | ❑ | 0 |
0.55 | 0.75 | 1.7 | 1.58 | FSA | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 0 | - | 5 | A | ❑ | 0 |
0.75 | 1 | 2.2 | 1.99 | FSA | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 0 | - | 7 | A | ❑ | 0 |
1.1 | 1.5 | 3.1 | 2.69 | FSA | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 1 | - | 1 | A | ❑ | 0 |
1.5 | 2 | 4.1 | 3.48 | FSA | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 1 | - | 5 | A | ❑ | 0 |
2.2 | 3 | 5.9 | 5.18 | FSB | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 2 | - | 2 | A | ❑ | 0 |
3 | 4 | 7.7 | 6.76 | FSB | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 3 | - | 0 | A | ❑ | 0 |
4 | 5 | 10.2 | 8.95 | FSB | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 4 | - | 0 | A | ❑ | 0 |
5.5 | 7.5 | 13.2 | 11.88 | FSC | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 5 | - | 5 | A | ❑ | 0 |
7.5 | 10 | 19 | 17.11 | FSC | 6SL352 | ❑ | - | ❑ | X | ❑ | ❑ | 7 | - | 5 | A | ❑ | 0 |
Article No. supplements | |||||||||||||||||
Brake control |
|
|
|
|
|
|
|
|
|
|
|
| |||||
180 V DC (independent of the line voltage) *) | 0 |
|
|
|
|
|
|
|
|
|
|
| |||||
380 ... 480 V AC (such as line voltage) | 1 |
|
|
|
|
|
|
|
|
|
|
| |||||
Operating options |
|
|
|
|
|
|
|
|
|
| |||||||
Without operating option *) | 0 |
|
|
|
|
|
|
|
|
| |||||||
Repair switch | 1 |
|
|
|
|
|
|
|
|
| |||||||
Local remote control | 2 |
|
|
|
|
|
|
|
|
| |||||||
Repair switch and local remote control | 3 |
|
|
|
|
|
|
|
|
| |||||||
Connection type | Fieldbus communication | I/O | Motor | 380 ... 480 V AC | 24 V DC |
|
|
|
|
|
|
|
| ||||
Cable gland with daisy chain | without | Cable gland *) | A | 0 |
|
|
|
|
|
| |||||||
Cable gland | Power supply integrated | H | 0 |
|
|
|
|
|
| ||||||||
M12 | Cable gland *) | A | 2 |
|
|
|
|
|
| ||||||||
M12 | Cable gland | A | 6 |
|
|
|
|
|
| ||||||||
Q8/0 | Cable gland | R | 0 |
|
|
|
|
|
| ||||||||
Cable gland | 2 × Power M12 6) | R | 1 |
|
|
|
|
|
| ||||||||
Cable gland | Power supply integrated | H | 2 |
|
|
|
|
|
| ||||||||
M12 | Cable gland | Power supply integrated | H | 6 |
|
|
|
|
|
| |||||||
Plug-in connection without daisy chain | M12 | M12 | Q8/0 | Q4/2 | 7/8" 4) | B | 0 |
|
|
|
|
|
| ||||
Q4/2 | Power M12 6) | B | 4 |
|
|
|
|
|
| ||||||||
Quickon 5) | Power M12 4) | C | 0 |
|
|
|
|
|
| ||||||||
MQ15 5) | Power M12 4) | D | 0 |
|
|
|
|
|
| ||||||||
Q4/2 | Power supply integrated | K | 0 |
|
|
|
|
|
| ||||||||
Quickon 5) | Power supply integrated | L | 0 |
|
|
|
|
|
| ||||||||
MQ15 5) | Power supply integrated | M | 0 |
|
|
|
|
|
| ||||||||
Plug-in connection with daisy chain | M12 | M12 | Q8/0 | 2 × Q4/2 | 2 × 7/8" *) 4) | E | 0 |
|
|
|
|
|
| ||||
2 × Power M12 6) | E | 4 |
|
|
|
|
|
| |||||||||
Power supply integrated | N | 0 |
|
|
|
|
|
| |||||||||
Fieldbus communication |
|
| |||||||||||||||
AS-Interface 7) | A |
| |||||||||||||||
Without fieldbus communication | B |
| |||||||||||||||
PROFINET, EtherNet/IP 7) | F |
|
*) If "brake voltage 180 V DC" and "without operating option" are selected in conjunction with one of the connection types A0, A2 or E0, the delivery time changes from "standard delivery time" to "delivery ex stock".
1) Rated power based on the rated output current IN. The rated output current IN is based on the duty cycle for high overload (HO).
2) The rated output current IN is based on the duty cycle for high overload (HO). These current values are valid for 400 V or 480 V and are specified on the rating plate of the converter.
3) The input current depends on the motor load and line impedance. The input currents apply for load at rated power for a line impedance corresponding to uK = 4 %. The current values are specified on the rating plate of the converter.
4) Plug-in connectors not available with fieldbus communication AS-Interface.
5) Not suitable for UL applications (FSA and FSB). Not available for FSC.
6) Version cannot be ordered with fieldbus communication AS-Interface.
7) The connection types A0 and H0 are not possible for fieldbus communication (AS-Interface, PROFINET or EtherNet/IP).