西门子CPU1211C*处理单元
  • 西门子CPU1211C*处理单元
  • 西门子CPU1211C*处理单元

产品描述

货期 安装方式现场安装 LD指令处理器硬PLC I/O点数128 功能控制逻辑模组 工作电压120/380V 输出频率45Hz 处理速度0.02μs 数据容量1000 产品认证CE 环境温度40℃ 环境湿度80℃ 重量0.2kg 销售范围全国 质保日期质保一年 西门子产品系列自动化设备全系列 产品询价随时 产品包装全新 加工定制

西门子CPU1211C*处理单元

西门子CPU1211C*处理单元

微信截图_20220911165952


MOTION-CONNECT connection systems

MOTION‑CONNECT cables are suitable for use with many different types of machine tools and production machinery.

The following variants of MOTION‑CONNECT cable are available as fully-assembled power and ** cables or sold by the meter:

MOTION‑CONNECT 500


Cost-effective solution for predominantly fixed routing

Suitable for low mechanical loading

Tested for traversing paths of up to 5 m (16.4 ft)


MOTION‑CONNECT 800PLUS


Meets requirements for use in cable carriers

Suitable for high mechanical loading

Oil resistance

Tested for traversing paths of up to 50 m (164 ft)


MOTION‑CONNECT 400 (only for SIMOTICS S-1FS2 motors)


Extremely chemically resistant FEP jacket (especially against common cleaning agents and disinfectants used in the F&B industry)

With integrated pressure compensation tube

Not suitable for repeated bending stress!



优势

Pre-assembled MOTION‑CONNECT cables provide high quality and impeccable system-tested functionality.

SPEED-CONNECT

Connectors with SPEED-CONNECT quick-release locks enable fast, stable and reliable connections. All that is required to attain stable interlocking and a secure connection is less than a quarter turn of the lock nut of the connector. Tools are not required.

Cables with SPEED‑CONNECT connectors supplement the previous offering of MOTION‑CONNECT cables with full-thread connectors.

应用

MOTION‑CONNECT cables are intended for use in machines. They are not suitable for building technology applications or outdoor installation.

MOTION-CONNECT cables have been tested in a cable carrier with horizontal traversing paths and have also been designed for this type of application. They are not self-supporting.

The pre-assembled cables can be ordered in length units of 10 cm (3.94 in) and can be extended, if necessary.

When cable lengths (basic cables and extensions) are determined for the systems and applications described in this catalog, the technically permissible maximum cable lengths (e.g. 25 m (82 ft)) specified in the catalog must be observed. Malfunctions can occur if longer cables are used. Siemens assumes no liability for correct transmission of **s or power in this case.

Compatibility between SPEED‑CONNECT and full-thread connectors:

Connector on motor with external thread

Connector with cap nut on cable

Compatibility

SPEED‑CONNECT

SPEED‑CONNECT

✓ 

SPEED‑CONNECT

Full-thread

✓ 

Full-thread

Full-thread

✓ 

Full-thread

SPEED‑CONNECT



功能

The cables must be removed from the drum without twisting, i.e., the cables must be unwound and must never be lifted over the drum flange in loops.

To maximize the service life of the cable carrier and cables, cables in the carrier made from different materials must be separated by spacers in the cable carrier. The spacers must be filled evenly to ensure that the position of the cables does not change during operation. The cables should be distributed as symmetrically as possible according to their weights and dimensions. Cables with very different outer diameters should also be separated by spacers.

When inserting pre-assembled cables into the cable carrier, do not pull at the connector, as this may damage the strain relief or cable clamping.

The cables must not be fixed in the cable carrier. They must be freely movable.

The cables must be able to be moved without applying force in particular in the bending radii of the carrier. The specified minimum bending radius must be adhered to.

The cable fixings must be attached at both ends at an appropriate distance away from the end points of the moving parts in a dead zone.

MOTION‑CONNECT cables are tested in a cable carrier. The cables are attached at one end by means of strain relief to the moving ends of the cable carrier. Strain relief is applied over a wide area of the cable jacket surface without crimping the cable.

Cables must be installed in accordance with the instructions supplied by the cable carrier manufacturer.

Note:

If, for example, pre-assembled cables are installed in a cable carrier in such a way that the connector would inhibit assembly, pre-assembled cables without assembled connector can also be supplied (power and ** cables 1)). Depending on the version, the contacts of the cables are crimped and the connector is supplied separately. After installing the cables, the customer assembles the connector.

In case of vibration load and with horizontal or vertical cable entries, we recommend that the cable is additionally fixed if between the cable strain relief on the cable carrier and the terminal at the motor part of the cable is hanging loose or is not routed. To prevent machine vibrations being transmitted to the connectors, the cable should be fixed at the moving part where the motor is mounted.

Representation in connection overviews

Symbol

Explanation

 

Connector with pin contacts

 

Connector with socket contacts

 

Exposed core ends

 

End sleeves

 

Cable must be supplied by the customer



1) Not for DRIVE‑CLiQ ** cables.

特性曲线

Characteristic curves for MOTION‑CONNECT 800PLUS

The e area beneath the characteristic curve represents the potential range of use for the cables. The characteristic curves represent the tested operating points.

Permissible acceleration for MOTION‑CONNECT 800PLUS ** and power cables up to 16 mm2

Permissible acceleration for MOTION‑CONNECT 800PLUS cables of 25 mm2, 35 mm2, and 50 mm2

多信息

Current carrying capacity for power and ** cables

The current carrying capacity of PVC/PUR-insulated copper cables is specified in the table for installation types B1, B2, C, and E under continuous operating conditions with reference to an ambient air temperature of 40 °C (104 °F). For other ambient temperatures, the values must be corrected by the derating factors from the table.

Cross-section

Current carrying capacity
rms AC 50/60 Hz or DC in amps for installation type

 

B1

B2

C

E

mm2

Single-core cables in conduits or installation ducts

Multi-core cables in conduits or installation ducts

Multi-core cables, vertically or horizontally on walls/open, without conduits and installation ducts/with contact

Multi-core cables, horizontally or vertically on perforated cable racks/open, without conduits or installation ducts/with contact

Electronics1)

0.2

4.3

4.4

4.4

0.5

7.5

7.5

7.8

0.75

9

9.5

10

Power2)

0.38

6.2

6.1

7.1

7.4

0.75

8.6

8.5

9.8

10.4

1

10.3

10.1

11.7

12.4

1.5

13.5

13.1

15.2

16.1

2.5

18.3

17.4

21

22

4

24

23

28

30

6

31

30

36

37

10

44

40

50

52

16

59

54

66

70

25

77

70

84

88

35

96

86

104

110

50

117

103

125

133

70

149

130

160

171

95

180

165

194

207

120

208

179

225

240



1) One control circuit pair.

2) One symmetrically loaded three-phase AC cable.

Derating factors for PVC/PUR-insulated power and ** cables

Ambient air temperature
°C (°F)

Derating factor
acc. to EN 60204‑1, Table D.1

30 (86)

1.15

35 (95)

1.08

40 (104)

1

45 (113)

0.91

50 (122)

0.82

55 (131)

0.71

60 (140)

0.58



Note:

Derating for MOTION-CONNECT 400 analogously according to EN 60204-1.



http://yan6789.b2b168.com
产品推荐

Development, design, production and sales in one of the manufacturing enterprises

您是第291130位访客
版权所有 ©2024 八方资源网 粤ICP备10089450号-8 浔之漫智控技术(上海)有限公司 保留所有权利.

浔之漫智控技术(上海)有限公司 保留所有权利.

技术支持: 八方资源网 八方供应信息 投诉举报 网站地图