西门子CPU 6ES7215-1HG40-0XB0
  • 西门子CPU 6ES7215-1HG40-0XB0
  • 西门子CPU 6ES7215-1HG40-0XB0

产品描述

货期 安装方式现场安装 LD指令处理器硬PLC I/O点数128 功能控制逻辑模组 工作电压120/380V 输出频率45Hz 处理速度0.02μs 数据容量1000 产品认证CE 环境温度40℃ 环境湿度80℃ 重量0.2kg 销售范围全国 质保日期质保一年 西门子产品系列自动化设备全系列 产品询价随时 产品包装全新 加工定制

西门子CPU 6ES7215-1HG40-0XB0

西门子CPU 6ES7215-1HG40-0XB0

System overview

概述

SIMATIC MICRO-DRIVE drive system, PDC Drives, PDC100, PDC100F, PDC600, PDC600F, PDC1000 V1 variants

Drive controller modules for ET200SP
SIMATIC MICRO-DRIVE F-TM StepDrive ST, ServoDrive HF und ServoDrive ST

First-class drive system in the protective extra-low voltage range

The requirements for motion control tasks in automation are ever increasing and are becoming more and more multi-faceted and complex. Digitalization is bringing about new solution approaches, regardless of the industry or application.

Fit for digitalization with SIMATIC MICRO-DRIVE

The SIMATIC MICRO-DRIVE drive system allows you to make a perfect entry into the world of digitalization. Thanks to Totally Integrated Automation (TIA), converters and motors are completely integrated into the Siemens automation environment and can be easily selected using the TIA Selection Tool and configured using the TIA Portal. A wide range of tools for the complete machine building cycle ensures efficient engineering and fast commissioning. Machine data is made available through MindSphere, the cloud-based, open IoT operating system from Siemens.

Well designed, flexible and fit for the future

SIMATIC MICRO-DRIVE is an extremely versatile, seamless and safety-oriented drive system that covers a wide range of applications in the protective extra-low voltage range.

It comprises the SIMATIC MICRO-DRIVE PDC Drives and TM Drives, as well as versatile EC motors and plug-in cables. The right controllers from the SIMATIC portfolio from Siemens optimally round out the motion control functions of this future-proof solution.

The F-TM StepDrive ST completes the portfolio within the range of controlling stepper motors.

In combination with EC Motors and stepper motors up to 280 W the F-TM ServoDrive HF allows positioning and speed control in very confined spaces. The triple overload capability and the support of BiSS-C Multiturn encoders extend the scope of applications.

Can be combined with motors and plug-in cables from selected Siemens Product Partners

To ensure that all of the requirements in drive technology are met in the best way possible, the SIMATIC MICRO-DRIVE drive system is compatible with individual and supplementary motors (ermotoren, ebm-papst) and plug-in cables (Harting, KnorrTec) from well-established Siemens Product Partners. This allows an optimal combination of suitable products from proven product partners for the individual application.

Strong in classic and innovative applications

SIMATIC MICRO-DRIVE is the ideal drive in numerous application areas. The system stands out when executing positioning tasks in production and manufacturing as well as in innovative application domains. Examples include drives for storage and retrieval machine shuttles and high bay racking systems, driverless transport systems as well as medical applications such as safely and reliably moving MRT examination tables and automatically aligning ceiling-mounted devices in radiographic applications.

For all applications

Moving

Energy-efficient and rugged solutions for basic conveyor technology with roller or chain conveyors, for hoisting gear and elevators – as well as for storage and retrieval machines – and always with Safety Integrated on board.

Processing

Ideal solution for continuous processes with simple speed and torque accuracy, for example with extruders, centrifuges, agitators an all types of production machines – motion control, isochronous communication (only for SIMATIC MICRO-DRIVE PDC Drives) and Safety Integrated.

Positioning

SIMATIC MICRO-DRIVE is the solution for 24/48 V DC applications: The positioning of individual axes and even the coordinated interpolation of several axes – such as in complex robotic applications – can be achieved easily.

Simple commissioning of SIMATIC MICRO-DRIVE PDC Drives through One Button Tuning and TIA Portal (V15 SP1 or higher)

Commissioning and engineering are possible with TIA Portal (V15 SP1 or higher). The tool for configuration, commissioning and diagnostics has been optimized with regard to the consistent utilization of the TIA Portal advantages – one shared work environment for PLC, HMI and drives.

For more information, see the Engineering tools section.

Safety Integrated

The integrated safety functions provide highly effective, application-oriented protection for personnel and machinery (terms as defined in IEC 61800-5-2).

The following Safety Integrated functions are included (not all of the functions are included in all of the drive controllers):


Safe Torque Off (STO) 1)

Safe Stop 1 (SS1, only for failsafe variants, e.g. PDC100F)

Safely-Limited Speed (SLS, only for failsafe variants, e.g. PDC100F)

New function: Safely-Limited Torque (SLT, only for failsafe variants)
Monitoring of motor current and torque during operation by means of safely-limited torque

Safe Speed Monitor (SSM, only for failsafe variants, e.g. PDC100F)


The Safety Integrated functions are fully integrated into the drive system (only for failsafe variants, e.g. PDC100F).

The Safety Integrated functions are implemented electronically and therefore require no additional installation effort or space in the control cabinet. Furthermore, the costs are considerably lower than for externally implemented monitoring functions.

The Safety Integrated functions can be easily put into operation via the TIA Portal (V15 SP1 or higher) and activation through a SIMATIC controller via PROFIsafe.

1) Does not apply for PDC1000 V1

Perfect combination with SIMATIC S7-1500, SIMATIC S7-1500 T-CPU, SIMATIC ET 200SP Open Controller via PROFINET or SIMATIC ET 200SP

Communication with the higher-level control takes place via PROFINET. For optimal interaction between the controller and the SIMATIC MICRO-DRIVE drive system, SIMATIC S7-1200, SIMATIC S7-1500, SIMATIC S7-1500 T-CPU, SIMATIC ET 200SP Open Controller can be used as the control system.

The SIMATIC MICRO-DRIVE PDC Drives features an integrated PROFINET IRT communication interface with a communication cycle of up to 1 ms for connecting to a control system.

Standardized protocols for linking to a higher-level control with RT and IRT are supported – the PROFIdrive profile for positioning mode and the PROFIsafe profile for safety-oriented communication. Functions such as Shared Device, ring redundancy, and PROFIenergy are also possible.

All from a single source: Through the use of Motion Control functionalities in the controller, the combination of converter and SIMATIC S7 automation system or a controller allows ideally harmonized engineering. As a result, commissioning times are shortened.

Technology objects and Motion Control blocks of the higher-level controller provide numerous possibilities of motion, such as continuous operation, positioning, synchronous operation, coordinated motion of multiple axes, cam disks, or interpolation.

Siemens offers tested SIMATIC PLC/HMI application examples for connection of the drive system to a SIMATIC control system:

www./sinamics-applications

Further information on the SIMATIC S7-1500, SIMATIC S7-1500 T-CPU controllers and SIMATIC ET 200SP Open Controller is available in the ST 70 Catalog and on the internet at

www./simatic-s7-1500

Example: communication via PROFINET with SIMATIC MICRO-DRIVE PDC Drives

Connection example: SIMATIC MICRO-DRIVE drive system, PDC Drives, PDC100 variant

Can be used worldwide

In addition to the usual approvals, the UL approval for the North American market has also been requested for the SIMATIC MICRO-DRIVE drive system. Thus, the SIMATIC MICRO-DRIVE drive system is available for worldwide use.

Further information

Detailed information on the SIMATIC MICRO-DRIVE drive system, including the latest technical documentation (brochures, tutorials, dimensional drawings, certificates, equipment manuals and operating instructions), is available on the internet at:

www./micro-drive

and also via the TIA Selection Tool:

www./tia-selection-tool




http://yan6789.b2b168.com
产品推荐

Development, design, production and sales in one of the manufacturing enterprises

您是第285505位访客
版权所有 ©2024 八方资源网 粤ICP备10089450号-8 浔之漫智控技术(上海)有限公司 保留所有权利.

浔之漫智控技术(上海)有限公司 保留所有权利.

技术支持: 八方资源网 八方供应信息 投诉举报 网站地图