Power supply unit
SIDOOR Transformer
The SIDOOR TRANSFORMER and SIDOOR TRANSFORMER UL are standard power supply units operated with 220-240 V AC, 50/60 Hz, from the SIDOOR product range. They can be used for controllers capable of controlling masses of up to 400 kg.
Article number | 6FB1112-0AT20-2TR0 | 6FB1112-0AT21-2TR0 | |
---|---|---|---|
SIDOOR TRANSFORMER | SIDOOR TRANSFORMER UL | ||
Installation type/mounting |
|
| |
Mounting type | Hexagon head bolt M6, L > 70 mm | ||
Supply voltage |
|
| |
permissible range, lower limit (AC) | 220 V | ||
permissible range, upper limit (AC) | 240 V | ||
relative symmetrical tolerance of the supply voltage | 10 % | ||
Line frequency |
|
| |
● permissible range, lower limit | 50 Hz | ||
● permissible range, upper limit | 60 Hz | ||
Mains filter |
|
| |
● integrated | Yes | ||
Input current |
|
| |
Current consumption, max. | 1.6 A | ||
Operational current of fuse protection at input, min. | 6 A | ||
Operational current of fuse protection at input, max. | 10 A | ||
Tripping characteristic class of fuse protection at input | D6, C10 | ||
Output voltage |
|
| |
RMS value (pulsating DC voltage at full load) | 17.3 V; at 230 V AC | ||
RMS value (pulsating DC voltage at full load), min. | 16.5 V | ||
RMS value (pulsating DC voltage at full load), max. | 18 V | ||
RMS value (pulsating DC voltage at 0.7 mA peak current), max. | 27 V; At 264 V AC | ||
Output current |
|
| |
Current output (rated value) | 14.3 A; t on 2 s / t off 8 s | ||
Power |
|
| |
Emitted active power, max. | 115 W; Average value above 10 s | ||
Standards, approvals, certificates |
|
| |
CE mark | Yes | ||
EAC (formerly Gost-R) | Yes | ||
RoHS conformity | Yes | ||
China RoHS compliance | Yes | ||
Standard for EMC | EN 12015 / EN 12016 / EN 61000-6-2 / EN 61000-6-3 / EN 61000-3-2 / EN 61000-3-3 | ||
Standard for safety | Low Voltage Directive (LVD) 2014/35/EU | UL 61010-1, CSA C22.2 No. 61010-1-12, Low Voltage Directive (LVD) 2014/35/EU | |
Ambient conditions |
|
| |
Ambient temperature during operation |
|
| |
● min. | -20 °C | ||
● max. | 55 °C | ||
● Remark | No direct exposure to the sun | ||
Ambient temperature during storage/transportation |
|
| |
● Storage, min. | -20 °C | ||
● Storage, max. | 70 °C | ||
● Transportation, min. | -40 °C | ||
● Transportation, max. | 70 °C | ||
Altitude during operation relating to sea level |
|
| |
● Installation altitude above sea level, max. | 2 000 m | ||
Relative humidity |
|
| |
● No condensation, min. | 10 % | ||
● No condensation, max. | 93 % | ||
Cables |
|
| |
Cable length | |||
● Input side | 2 m | ||
● Output side | 1.5 m | ||
Connection method |
|
| |
Design of electrical connection at input | SCHUKO connector DIN 49.441, CEE7/VII | equipped with ferrules | |
Dimensions |
|
| |
Width | 145 mm | ||
Height | 65 mm | ||
Depth | 126 mm |