6BK1943-2AA00-0AA2 SIPLUS HCS4300 POM4320 母线安装(IEC) 9 个输出每个较大 6400 W(400 VAC 时) |
6BK1943-2CH00-0AA0 SIPLUS HCS4300 POM4320 高端背板安装 UL 6 个输出端,每个较大 12800 W(400 VAC 时 |
Module (encapsulated) in a metal enclosure.
There are 6 versions:
POM4320 busbar mounting (IEC): a current of up to 16 A can be used per output
POM4320 busbar mounting (UL): a current of up to 15 A can be used per output
POM4320 rear panel mounting (IEC): a current of up to 16 A can be used per output
POM4320 rear panel mounting (UL): a current of up to 15 A can be used per output
POM4320 Highend busbar mounting: a current of up to 60 A can be used per output
POM4320 Highend rear panel mounting: a current of up to 60 A can be used per output
Heat dissipation by fan fitted to top of module.
Internal serial interface.
Three diagnostics LEDs for displaying module faults.
POM4320: 9 diagnostics LEDs for displaying output errors.
POM4320 Highend: 6 diagnostics LEDs for displaying output errors.
Power triacs:
Protection of triacs and opto-triacs against overvoltages by Transil diodes
Transfer of the diagnostics information to the higher-level control system
Half-wave control:
This is the control method used in normal operation. At every zero crossover, the output is controlled depending on the parameterized setpoint value. The control variable is set to values between 0 and **.
Soft start:
Phase control is executed for a limited time in order to achieve a gradual warming of the emitters. Switches to half-wave control when the time has expired. The control variable is set to values between 0 and **.
Phase control:
Phase control is executed permanently in order to achieve even heat dissipation and avoid disruptive emitter flickering with low setpoints. Phase control can sometimes cause EMC interference on the power supply lines which then has to be filtered on the system side.
9 power outputs of 400 V/480 V each (3 outputs per phase)
Switching capacity per output:
POM4320 IEC busbar mounting and rear panel mounting: max. 6 400 W at 400 V or 7 680 W at 480 V
POM4320 UL busbar mounting and rear panel mounting: max. 6 000 W at 400 V or 7 200 W at 480 V
Switching capacity per POM:
POM4320 IEC busbar mounting and rear panel mounting: max. 57 600 W at 400 V or 69 120 W at 480 V
POM4320 UL busbar mounting and rear panel mounting: max. 54 000 W at 400 V or 64 800 W at 480 V
Notice: Short-wave halogen or infrared emitters, so-called flash emitters, often have a high switch-on current due to their relatively low cold resistance. This switch-on current can be a multiple of the rated current especially during the initial half-waves. This can lead to the fuse being triggered. There is a switching power limit of 4 000 W when using flash emitters.
6 power outputs of 230 V/277 V and 400 V/480 V each (2 outputs per phase)
Switching capacity per output:
POM4320 Highend busbar mounting and rear panel mounting:
- max. 7360 W at 230 V or 8864 W at 277 V
- max. 12 800 W at 400 V or 15 360 W at 480 V
Switching capacity per POM:
- max. 44 160 W 230 V or 53 184 W at 277 V
- max. 76 800 W at 400 V or 92 160 W at 480 V
3 power outputs with 2 outputs in parallel connection (each 1 outlet per phase)
Switching capacity per output:
POM4320 Highend busbar mounting and rear panel mounting:
- max. 13 800 W at 230 V or 16 620 W at 277 V
- max. 24 000 W at 400 V or 28 800 W at 480 V
Switching capacity per POM:
- max. 44 160 W 230 V or 53 184 W at 277 V
- max. 76 800 W at 400 V or 92 100 W at 480 V
Notice: Short-wave halogen or infrared emitters, so-called flash emitters, often have a high switch-on current due to their relatively low cold resistance. This switch-on current can be a multiple of the rated current especially during the initial half-waves. This can lead to the fuse being triggered. There is a limit to a switching capacity of 6000 W when using flash emitters at 400 V.
A fan for heat dissipation is mounted on the top. The fan is replaceable.
There is an NTC thermistor in the device for monitoring the internal temperature. This temperature-dependent resistor switches off the module power outputs when a certain internal temperature is reached.
POM4320 IEC busbar mounting and rear panel mounting: Two 16 A fuses are available for each power output in a fuse module that can be accessed from the front to protect the power triacs.
POM4320 UL busbar mounting and rear panel mounting: Two 15 A fuses are available for each power output in a fuse module that can be accessed from the front to protect the power triacs.
POM4320 Highend busbar mounting and rear panel mounting: One 32 A fuse is available for each power output in a fuse module that can be accessed from the front to protect the power triacs. Depending on the interconnection of the individual heating elements, the return line of the heating element can optionally be plugged into the available fuse holders of the fuse module.
Diagnostics functions are provided to detect the following faults as standard:
Implicit diagnostics means that the heating power is not influenced by the diagnostics themselves
Outgoing fuse is defective / triac at high resistance (exception: setpoint value 0%)
Incoming line fuse is defective
Triac has failed (exception: setpoint value **)
Connecting cable defective (short-circuit and interruption) or load is defective (short-circuit and interruption)
Monitoring of supply voltage
Additionally for POM4320 Highend:
Connecting cable defective (short-circuit and interruption) or load is defective (short-circuit and interruption) with emitters connected in parallel and residual current too high.
Internal compensation is carried out to compensate line voltage fluctuations
The function runs on the HCS master; it can be switched on and off by the user
The measured voltage values from each POM are available to the HCS master
Article number | 6BK1943-2AA00-0AA2 | 6BK1943-2AH00-0AA0 | 6BK1943-2BA00-0AA2 | 6BK1943-2CA00-0AA2 | 6BK1943-2CH00-0AA0 | 6BK1943-2DA00-0AA2 | |
---|---|---|---|---|---|---|---|
HCS POM4320 busbar mounting (IEC) | HCS POM4320 Highend busbar mounting | HCS POM4320 busbar mounting (UL) | HCS POM4320 panel mounting (IEC) | HCS POM4320 Highend panel mounting | HCS POM4320 panel mounting (UL) | ||
General information |
|
|
|
|
|
| |
Product type designation | POM4320 BUSBAR MOUNTING (IEC) | POM4320 Highend | POM4320 BUSBAR MOUNTING (UL) | POM4320 rear panel mounting (IEC) | POM4320 Highend | POM4320 rear panel mounting (UL) | |
Installation type/mounting |
|
|
|
|
|
| |
Mounting type | Busbar mounting | Backplane mounting | |||||
Mounting position | vertical | ||||||
Type of ventilation | Self-ventilation | ||||||
Supply voltage |
|
|
|
|
|
| |
Type of supply voltage | AC | ||||||
Rated value (AC) | 400 V; Phase - phase | 230 V; phase - neutral conductor | 400 V; Phase - phase | 230 V; phase - neutral conductor | 400 V; Phase - phase | ||
● Relative negative tolerance | 10 % | ||||||
● Relative positive tolerance | 30 % | ||||||
2nd rated value (AC) | 480 V; Phase - phase | 277 V; phase - neutral conductor | 480 V; Phase - phase | 277 V; phase - neutral conductor | 480 V; Phase - phase | ||
● Relative negative tolerance | 25 % | ||||||
● Relative positive tolerance | 8 % | ||||||
3rd rated value (AC) | 400 V; Phase - phase | 400 V; Phase - phase | |||||
● Relative negative tolerance | 10 % | 10 % | |||||
● Relative positive tolerance | 30 % | 30 % | |||||
4th rated value (AC) | 480 V; Phase - phase | 480 V; Phase - phase | |||||
● Relative negative tolerance | 25 % | 25 % | |||||
● Relative positive tolerance | 8 % | 8 % | |||||
Line frequency |
|
|
|
|
|
| |
● Rated value 50 Hz | Yes | ||||||
● Rated value 60 Hz | Yes | ||||||
● Relative symmetrical tolerance | 5 % | ||||||
Mains buffering |
|
|
|
|
|
| |
● Recovery time after power failure, typ. | 1 s | ||||||
Connection method |
|
|
|
|
|
| |
● Design of electrical connection for supply voltage | Busbar mounting, 3-pole + PE | Busbar adapter, 3-pole + N + PE | Busbar mounting, 3-pole + PE | Terminal, 3-pole + N + PE | Busbar mounting, 3-pole + PE | ||
— Connectable conductor cross-sections, solid | 1x (1.5 ... 50 mm²) | ||||||
— Connectable conductor cross-sections, finely stranded with wire end processing | 1x (1.5 ... 35 mm²) | ||||||
— Connectable conductor cross-sections for AWG cables | 1x (16 ... 1) | ||||||
— Cable cross-sections for N | 1x (0.2 ... 2.5 mm²) | 1x (0.2 ... 2.5 mm²) | |||||
Input voltage |
|
|
|
|
|
| |
device version of the power supply for electronics | Power supply via CIM | ||||||
Power |
|
|
|
|
|
| |
Active power input, max. | 8 W | 10 W | 8 W | 10 W | 8 W | ||
Power electronics |
|
|
|
|
|
| |
Type of load | Ohmic load | ||||||
Power capacity, max. | 57.6 kW; At 400 V AC | 76.8 kW; At 400 V AC | 64.8 kW; At 480 V AC | 57.6 kW; At 400 V AC | 76.8 kW; At 400 V AC | 64.8 kW; At 480 V AC | |
● For phase against phase with fan at 40 °C, max. | 57.6 kW; At 400 V AC | 76.8 kW; At 400 V AC | 64.8 kW; At 480 V AC | 57.6 kW; At 400 V AC | 76.8 kW; At 400 V AC | 64.8 kW; At 480 V AC | |
● For phase against neutral with fan at 40 °C, max. | 44.16 kW; at 230 V AC | 44.16 kW; at 230 V AC | |||||
Switching capacity current per phase, max. | 83 A | 80 A | 83 A | 105 A; 90 A (UL) | 80 A | ||
Short-time withstand current (SCCR) acc. to UL 508A | 100 kA | 100 kA | |||||
Control of heating elements |
|
|
|
|
|
| |
● Half-wave control | Yes | ||||||
● Soft start | Yes | ||||||
● Phase control | Yes | ||||||
Load connection type |
|
|
|
|
|
| |
● Star connection with neutral conductor (single-phase) | No | Yes | No | Yes | No | ||
● Open delta connection (single-phase) | Yes; Incoming fuse contained in the device | Yes; Incoming fuse in the device optionally possible | Yes; Incoming fuse contained in the device | Yes; Incoming fuse in the device optionally possible | Yes; Incoming fuse contained in the device | ||
● closed delta connection (2-phase) | No | Yes; Economy circuit | No | Yes; Economy circuit | No | ||
● Closed delta connection (3-phase) | No | Yes | No | Yes | No | ||
● Star connection with neutral conductor (2-phase) | No | Yes; Economy circuit | No | Yes; Economy circuit | No | ||
● star connection without neutral conductor (3-phase) | No | Yes | No | Yes | No | ||
● 2-pole switching | No | Yes; Phase - phase | No | Yes; Phase - phase | No | ||
Setpoint input |
|
|
|
|
|
| |
● Percent | Yes | ||||||
● Watts | No | Yes | No | Yes | No | ||
Heating power |
|
|
|
|
|
| |
● Number of digital outputs | 9 | 6; Possible parallel switching of 2 outputs | 9 | 6; Possible parallel switching of 2 outputs | 9 | ||
● Number of heating elements per output, max. | 1 | 5 | 1 | 5 | 1 | ||
● Output voltage for heating power | 400 V | 230 V | 400 V | 230 V | 400 V | ||
● 2nd output voltage for heating power | 480 V | 277 V | 480 V | 277 V | 480 V | ||
● 3rd output voltage for heating power | 400 V | 400 V | |||||
● 4th output voltage for heating power | 480 V | 480 V | |||||
● Power carrying capacity per output, min. | 200 W; At 400 V AC | 1 200 W; At 400 V AC | 240 W; At 480 V AC | 200 W; At 400 V AC | 1 200 W; At 400 V AC | 240 W; At 480 V AC | |
● Power carrying capacity per output, max. | 6 400 W; At 400 V AC | 12 800 W; At 400 V AC | 7 200 W; At 480 V AC | 6 400 W; At 400 V AC | 12 800 W; At 400 V AC | 7 200 W; At 480 V AC | |
— for heating elements with high in current, max. | 4 000 W; At 400 V AC | 6 000 W; At 400 V AC | 4 000 W; At 480 V AC | 4 000 W; At 400 V AC | 6 000 W; At 400 V AC | 4 000 W; At 480 V AC | |
● Output current for heating power | 16 A; max. | 32 A; max. | 15 A; max. | 16 A; max. | 32 A; max. | 15 A; max. | |
● Melting I2t value | 250 A²·s | 400 A²·s | 250 A²·s | 400 A²·s | |||
● Design of short-circuit protection per output | Fuse 16 A | Melting fuse 32 A | Melting fuse 20 A | Fuse 16 A | Melting fuse 32 A | Melting fuse 20 A | |
● Design of overvoltage protection | Transil Diode | ||||||
Connection method |
|
|
|
|
|
| |
● Design of electrical connection at output for heating and fan | plug, 3-pole with spring-type terminal, push-in | plug, 3-pole, with operating lever, push-in | plug, 3-pole with spring-type terminal, push-in | plug, 3-pole, with operating lever, push-in | plug, 3-pole with spring-type terminal, push-in | ||
— Connectable conductor cross-sections, solid | 1x (0.2 ... 10 mm²) | 1x (0.75 ... 16 mm²) | 1x (0.2 ... 10 mm²) | 1x (0.75 ... 16 mm²) | 1x (0.2 ... 10 mm²) | ||
— Connectable conductor cross-sections, finely stranded with wire end processing | 1x (0.25 ... 6 mm²) | 1x (0.75 ... 16 mm²) | 1x (0.25 ... 6 mm²) | 1x (0.75 ... 16 mm²) | 1x (0.25 ... 6 mm²) | ||
— Connectable conductor cross-sections for AWG cables, stranded | 1x (24 ... 8) | 1x (18 ... 4) | 1x (24 ... 8) | 1x (18 ... 4) | 1x (24 ... 8) | ||
Interfaces |
|
|
|
|
|
| |
Interfaces/bus type | system interface | ||||||
Interrupts/diagnostics/status information |
|
|
|
|
|
| |
Number of status displays | 12 | 9 | 12 | 9 | 12 | ||
LED status display | LED green = ready, LED yellow = heating on/off, LED red = error display, LED red = error for each channel | ||||||
Diagnostics function | Voltage diagnostics | Voltage and current diagnosis | Voltage diagnostics | Voltage and current diagnosis | Voltage diagnostics | ||