西门子模块代理商|海南PLC模块代理商
西门子模块代理商|海南PLC模块代理商
SONOKIT flowmeter (with FUS060 or FUS080) |
SONOKIT is a transit time based ultrasonic flowmeter for retrofitting on existing pipelines.
The kit offers all necessary parts and special tools to make the installation as 1-path or 2-path flowmeter.
The set is made for installation on empty pipes or pipes under pressure without process shut-down (hot-tap).
Please contact Siemens for further information on hot-tap tools and instructions.
SONOKIT has in-line transducers (in contact with media) which assure superior accuracy and performance.
Cost-effective solution – contains all the necessary components for retrofitting
SONOKIT is easy to install in pipeline sizes DN 200 to DN 3000 (8” to 120”) 1-path DN 100 to DN 2400 (4” to 96”)
No bypass installation necessary – withstands pressures up to 40 bar (580 psi) and media temperatures between ‑20 °C and +200 °C (‑4 °F and +392 °F)
High accuracy – the bigger the pipe, the more accurate the result
Solid construction and no moving parts for a 100 % maintenance and obstruction-free flowmeter
The SONOKIT comes with transducers in IP68 enclosure
Available in a robust version that can be buried and withstands constant flooding
In-line transducers assure superior accuracy and performance
Automatic calculation of the calibration factor when pipe geometry data are entered in the transmitter
FST030 transmitter, modified for inline, HART or Modbus
FUS080 transmitter, battery or mains-powered
Raw water intake for water treatment plants
Water distribution systems
Irrigation systems
Power generation (energy and water)
District heating plants
Cooling water plants within the industry and in power stations
Systems within the oil and refinery business
*age treatment plants
Plants transporting non-conductive liquids
The SONOKIT package box contains all necessary parts to build an ultrasonic flowmeter on existing pipes depending on choices at ordering:
Papers to wrap around pipes for alignment of sensors
Transducer alignment tools
Mounting plates, transducer holders and SONO 3200 transducers
Transducer cables
SITRANS FUS060 or FUS080 transmitter for wall mounting
For pipes bigger DN 500 (20") please order FST030 Transmitter seperately (FDK-085X6329)
The transmitter related to this system is the SITRANS FUS080 or FST030. See Technical specifications for FUS060 and FUS080.
Accuracy | |
Typical, depending on accuracy of measurements of installation | 2-path: ≤ ± (0.5 … 1.5 %) |
1-path: ≤ ± (1 … 3 %) | |
Note: |
Requirements for pipes | |
Size | FUS060: FUS080: |
Line pressure | max. 40 bar (580 psi) |
Media temperature | |
Standard version | -10 … +200 °C (14 … 392 °F) |
ATEX Ex d version (FUS060) | -20 … +180 °C (-4 … +356 °F) |
ATEX Ex i version (FUS060) | -10 … +190 °C (14 … 374 °F) |
Ambient temperature sensor | |
Standard and Ex-i version | -20 … +60 °C (-4 … +140 °F) |
Ex d version | -20 … +180 °C (-4 … +356 °F) |
Transducer enclosure/approvals/certificates | |
Standard version | IP67 (NEMA 6)/IP68 (NEMA 6P) |
Ex approval | System ATEX approval for SONO 3200 Ex i transducers together with transmitter FUS060-Ex: |
ATEX II 2G Ex d T3-T6 Gb with SONO 3200 Ex d transducers (for standard FUS060 transmitter, installed outside of Ex zone) | |
Material certificates | EN 10204-3.1 material certificate on transducer mounting parts |
Transducer materials | |
Terminal housing | Standard version: |
Transducer body | Standard version: |
Materials of existing pipeline | |
Steel | Transducer holder: EN 10273 or EN 10216 (P235GH) |
| Mounting plates 1): EN 10273 or EN 10216 (P235GH) |
Concrete | Transducer holder: Stainless steel AISI 316 or similar |
| Mounting plates 1): (not included) |
Stainless steel | Transducer holder: Stainless steel AISI 316 or similar |
| Mounting plates 1): Stainless steel AISI 316 or similar |
Pipe wall thickness | |
Steel pipe (AISI 316 and St. 37.2 or corresponding material) | Transducer and holder available in length L = 160, allowing a pipe wall thickness up to 20 mm (0.79”) |
Concrete pipe | Transducer and holder available in length L = 230, allowing a pipe wall thickness up to 200 mm (7.9”) and pipe sizes ≥ DN 600. |
Dimension of the package box | 856 x 390 x 344 mm |
(L x W x H) | |
Weight example of a package | approx. 53 kg (116.8 lb) |
(standard 2-path with FUS060) | |
Certificates and approvals | |
Conformity certificate | The devices are supplied as standard with a Siemens Certificate of Conformity on a DVD. |
Material certificate | Material certificate for the transducer parts according to EN 10204-3.1 is optionally available. |
Approvals | No custody transfer approvals |
Information on PED approval:
The SONOKIT includes the pipe mounting parts only and therefore it cannot be PED-approved. After the installation, all installation-related activities (welding, pressure test etc.) are the responsibility of the customer.
1) Mounting plates are only included for empty pipe installation types (refer to selection "A"). For hot tap mounting the mounting plates are not included (refer to selection "B").
The space requirements (in mm) around the pipe for retrofitting a SITRANS F US ultrasonic flowmeter type SONOKIT are given below:
Empty pipe installation
Hot-tap installation
Potting kit for SONO 3200 terminal housing
Description | Article No. | |
---|---|---|
Potting kit for terminal box of SONO 3200 transducers for IP68/NEMA 6P (not for Ex sensors) | FDK:085L2403 |
Tools for SONO 3200 transducers and SONOKIT
Description | Article No. | |
---|---|---|
Extraction tool for replacement of SONO 3200 O-ring transducers under pressure and for hot-tapping (working conditions: typically water, max. 40 bar and max. 60 °C (max. 580 psi and max. 140 °F)) | | |
For transducer length: | ||
Up to 160 mm (6.3“) | FDK:085B5333 | |
Up to 230 mm (9.1“) | FDK:085B5335 | |
Angle measurement tool for SONOKIT | FDK:085B5330 | |
Hot-tap drilling tool for SONOKIT, the extraction tool is required, max. pressure 40 bar (580 psi) | FDK:085B5392 | |
Alignment tool for SONOKIT (typically for hot-tapping) | FDK:085B5393 | |
Description | Article No. | |
---|---|---|
Alignment rods-set for DN 100 … 650 (4" … 26"), ∅ = 25 mm, L = 500 mm, 3 pcs. | A5E02609214 | |
Alignment rods-set for DN 700 … 1900 (28" … 76"), ∅ = 25 mm, L = 500 mm, 6 pcs. | A5E02609215 | |
Alignment rods-set for DN 2000 … 3000 (80" … 120"), ∅ = 25 mm, L = 500 mm, 10 pcs. | A5E02609216 | |
Spanner key for tranducer mounting type SONO 3200 O-ring type | A5E02609218 | |
Tool set with various mounting/spare parts for SONOKIT installation | A5E02609219 |
Tranducer SONO 3200 spare parts, complete transducer with ½“-NPT cable glands
Transducer type | Material | Gasket | Pressure rating | Terminal housing | Approval | Temperature range | Length | Article No. | |
---|---|---|---|---|---|---|---|---|---|
O-ring | 316 SS | O-ring | PN 40 | Plastic PA 6.6 | | -20 … +100 (-420 … +212) | 160 (6.3) | A5E00839476 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | | -20 … +200 1) (-4 … +392) | 160 (6.3) | A5E00839435 | |
O-ring | 316 SS | O-ring | PN 40 | Plastic PA 6.6 | | -20 … +100 (-4 … +212) | 230 (9.41) | A5E00839477 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | | -20 … +200 1)(-4 … +392) | 230 (9.41) | A5E00839437 |
1) 316 SS housing for -20 … +200 °C (-4 … +392 °F) media temp. but cable glands only for -20 … +100 °C (-4 … +212 °F) ambient temperature
Transducer SONO 3200 spare parts, complete transducer with M20 cable glands
Transducer type | Material | Gasket | Pressure rating | Terminal housing | Approval | Temperature range [°C (°F)] | Length | Article No. | |
---|---|---|---|---|---|---|---|---|---|
O-ring | 316 SS | O-ring | PN 40 | Plastic PA 6.6 | | -20 … +100 (-4 … +212) | 160 (6.3) | FDK:085B5454 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | | -20 … +200 1) (-4 … +392) | 160 (6.3) | FDK:085B5455 | |
O-ring | 316 SS | O-ring | PN 40 | Plastic PA 6.6 | | -20 … +100 (-4 … +212) | 230 (9.41) | FDK:085B5458 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | Ex d 2) | -20 … +180 (-4 … +356) | 160 (6.3) | FDK:085B5452 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | Ex I 3) | -10 … +190 (14 … 374) | 160 (6.3) | A5E00836462 | |
O-ring | 316 SS | O-ring | PN 40 | 316 SS | | -20 … +200 2) (-4 … +392) | 230 (9.41) | FDK:085B5459 |
1) 316 SS housing for -20 … +200 °C (-4 … +392 °F) media temp. but cable glands only for -20 … +100 °C (-4 … +212 °F) ambient temperature
2) ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb
3) For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
Transducer SONO 3200 spare parts, transducer terminal housing with M20 cable glands
Type | Article No. | |
---|---|---|
Material: PA 6.6, Temperature range: -20 … +100 °C (-4 … +212 °F) | FDK:085B5501 | |
Material: AISI 316, Temperature range: -20 … +200 °C (-4 … +392 °F) | FDK:085B5504 | |
Material: AISI 316, Ex d 1), Temperature range: -20 … +180 °C (-4 … +356 °F) | FDK:085B5505 | |
Material: AISI 316, Ex i 2), Temperature range: -10 … +190 °C (14 … 374 °F) | A5E00835255 |
1) ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb
2) For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
Transducer SONO 3200 spare parts, transducer terminal housing with ½”-NPT cable glands
Type | Article No. | |
---|---|---|
Material: PA 6.6, Temperature range: -20 … +100 °C (-4 … +212 °F) | A5E00839460 | |
Material: AISI 316, Temperature range: -20 … +200 °C (-4 … +392 °F) | A5E00839427 |
Transducer SONO 3200 spare parts transducer body with insert as well as insert only
Temperature range [°C (°F)] | Gasket | Length [mm (inch)] | Article No. | |
---|---|---|---|---|
-20 … +200 (-4 … +392) | O-ring (FFKM O-ring material) 1) | 160 (6.3) | FDK:085B1406 | |
-20 … +200 (-4 … +392) | O-ring (FKM 602 O-ring material) 2) | 160 (6.3) | FDK:085B5510 | |
-20 … +200 (-4 … +392) | O-ring | 230 (9.41) | FDK:085B5511 |
1) Chemical resistant O-ring material. Body specially for Ex-approved transducers.
2) Body specially for standard transducers.
Transducer SONO 3200 gasket
Type | Pressure rating | Material | Temperature range [°C (°F)] | Article No. | |
---|---|---|---|---|---|
Gasket O-ring (3 pcs. for O-ring transducers) | PN 40 | FKM | -20 … +200 (-4 … +392) | FDK:085B1089 |