4
西门子PLC继电器CPU1212C
西门子电缆代理商
SIMATIC ET 200pro FC-2 frequency converter
The SIMATIC ET 200pro FC-2 frequency converter has the design of a SIMATIC ET 200pro module. It supplements the SIMATIC ET 200pro system range with distributed, speed-controlled drives. It is suitable for the open-loop and closed-loop control of asynchronous (induction) motors in a wide range of industrial applications. It is predestined for conveyor technology applications using drives networked via PROFIBUS and PROFINET, in particular in distributed designs without control cabinet with high degree of protection (IP65), when combining several drives. The modular, service-friendly concept is ideally suited to manufacturing processes with high plant standstill costs.
Modular drive solutions – therefore standardized mechatronic elements that can be individually tested
A control cabinet is not required, resulting in a smaller space requirement and lower cooling requirements
Long motor cables between converter and motor are not required
Less power losses
Reduced noise radiation
Reduced costs for shielded cables
No additional filters
Distributed configurations offer considerable benefits for conveyor systems with their extensive coverage (e.g. in the automotive and logistics sectors)
Siemens offers an innovative portfolio of frequency converters to optimally implement distributed drive solutions. The strengths of the individual members of the drive family permit simple adaptation to the widest range of application demands:
Identical connection systems
User-friendly commissioning and configuration tools
Products from the family of distributed drives:
SINAMICS G115D distributed drive system (wall and motor-mounted)
SINAMICS G120D frequency converters
SIMATIC ET 200pro FC-2 frequency converters
SIRIUS M200D motor starters
The distributed SIMATIC ET 200pro FC-2 frequency converters are already equipped with the integrated STO (Safe Torque Off) safety function, certified in accordance with IEC 61508 SIL 2 as well as EN ISO 13849-1 PL d and Category 3. It can be activated locally via the F-RSM or by means of PROFIsafe.
The STARTER commissioning tool (V4.4 and higher) plus the corresponding SINAMICS Support Package (SSP) supports the commissioning and maintenance of SIMATIC ET 200pro FC-2 frequency converters.
The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.
Hardware Support Packages (HSP) are available to integrate SIMATIC ET 200pro FC-2 in STEP7 classic.
TIA Portal is a powerful engineering framework providing full access to the whole digitized automation.
Hardware Support Packages (HSP) are available to integrate SIMATIC ET 200pro FC-2 in TIA Portal.
Quick and easy installation
Flexibility as SIMATIC ET 200pro modules can be freely combined with the frequency converter
No wiring outlay due to self-assembling communication and supply rails in the backplane bus with each additional module
The load voltage is routed to downstream frequency converters or motor starters with minimal installation costs through pre-assembled power jumper plugs (max. 25 A).
Accelerated engineering, fast installation and commissioning
Easy combination and expansion of converter functionality using I/O modules or RSM isolator modules within the distributed station
Module replacement possible without interrupting communication to the SIMATIC ET 200pro station and the other modules within SIMATIC ET 200pro
No configuration effort required or reduction of space requirements and installation expenditure for the braking resistor due to line-commutated energy recovery
Parameter assignment via IOP‑2 Handheld, STARTER and optional memory card as parameter storage medium
Standard mini USB interface for commissioning
Low-cost and uniform solutions
Communication via PROFIBUS and PROFINET (copper or POF fiber-optic cables) including the corresponding interface module
Safety Integrated functionality (STO) already integrated as standard
Activation of the fail-safe function (STO) of the frequency converter locally via the Safety Local isolator module F‑RSM or via PROFIsafe with the F‑Switch PROFIsafe module
The frequency converter controls the speed of induction motors steplessly.
The modular, service-friendly concept of the frequency converter is ideally suited to manufacturing processes with high plant standstill costs.
Ideal solutions can be created using several frequency converters combined in one distributed station when drives are operated in the same area or for the same purposes.
The frequency converter handles both frequency control for simple applications and sensorless vector control (SLVC) for more complex drive tasks. It also handles the optimum control of a motor brake, if used.
The converter also supports torque control, for example, for applications with mechanically coupled drives.
The benefits of regenerative feedback lie primarily in the reduction in configuring overhead (no braking resistor necessary), reduced installation costs and lower space requirements.
The STO safety function integrated as standard significantly reduces the overhead for drive solutions in plant sections where there is a hazard potential.
The SIMATIC ET 200pro FC‑2 distributed frequency converter is a compact frequency converter for standard drives which has the design of a SIMATIC ET 200pro module. Each SIMATIC ET 200pro FC‑2 frequency converter includes both the Control Unit as well as the Power Module in one unit. In addition, there is a backplane bus module for integrating the frequency converter in the SIMATIC ET 200pro system bus.
SIMATIC ET 200pro FC‑2 frequency converter
The SIMATIC ET 200pro FC‑2 frequency converter supplements the SIMATIC ET 200pro system range with distributed, speed-controlled drives. The frequency converter offers, in combination with the other modules of the modular SIMATIC ET 200pro system, solutions which have been exactly tailored to the plant/system and allows, through the combination of several frequency converters in one distributed station, ideal solutions when drives are operated in the same area or for the same purposes.
SIMATIC ET 200pro station with two SIMATIC ET 200pro FC‑2 converters
It is completely embedded in the SIMATIC ET 200pro system and offers all the system advantages such as cabinet-free installation, easy mounting on the module rack, reduction of the wiring outlay due to self-assembling communication and supply rails in the backplane bus, comprehensive diagnostic mechanisms and high availability thanks to replaceability without affecting other modules in the SIMATIC ET 200pro station.
The certified STO safety function integrated as standard ensures that persons and machines are protected from the dangerous movement of machines. Integration of the safety system into the drive also simplifies the machine architecture and supports system-wide diagnostics.
Active and dynamic braking of the motor is possible without incurring any additional costs. The generated braking energy is fed back into the power supply, so there is no need for a braking chopper and braking resistors. To ensure full motor protection, a temperature sensor of the PTC type, bimetal, KTY or Pt1000 can be connected. The integrated 180 V DC brake control at 400 V line voltage (Uline × 0.45 = brake voltage) allows the direct activation of a motor holding brake and makes a rectifier in the motor terminal box superfluous.
In combination with an SD memory card, the slot for the optional memory card can be used to save the parameter settings in order to facilitate fast replacement of modules with automatic reparameterization.
SIMATIC ET 200pro FC‑2 frequency converters use the control modes frequency control and sensorless vector control. The SIMATIC ET 200pro FC‑2 frequency converter also supports torque control, for example, for applications with mechanically coupled drives. The innovative power unit concept capable of energy recovery helps save energy.
Options for parameter assignment:
STARTER, the graphical parameterization tool for Siemens drives
The fieldbus
A point-to-point connection via a mini USB interface
The optical interface for connection of an IOP-2 Handheld
A parameter set download from the SIMATIC controller is also possible.
The distributed SIMATIC ET 200pro FC-2 frequency converters feature the following interfaces as standard:
Line supply connection via Q4/2 (socket)
Motor connection via Q8 (connector) including control of the motor brake and temperature sensor
Power output via Q4/2 (connector) for looping the 400 V 3 AC further to a subsequent frequency converter or motor starter from the SIMATIC ET 200pro system
Connection example for SIMATIC ET 200pro FC-2
Distributed frequency converter | SIMATIC ET 200pro FC-2 | ||||
|---|---|---|---|---|---|
Selection features | |||||
Integrated safety functions acc. to IEC 61508 SIL 2 and EN ISO 13849-1 PL d and Category 3 | Safe Torque Off (STO) Control of the integrated safety function via the Safety Local isolator module F-RSM or via F-Switch PROFIsafe | ||||
Electrical specifications | |||||
Line voltage | 380 ... 480 V 3 AC ±10 % | ||||
Power |
| ||||
With an ambient temperature of 0 ... 55 °C (32 °F ... 131 °F) | 1.1 kW | ||||
With an ambient temperature of 0 ... 45 °C (32 °F ... 113 °F) | 1.5 kW | ||||
Rated input current/output current |
| ||||
With an ambient temperature of 0 ... 55 °C (32 °F ... 131 °F) | 2 A/3.5 A | ||||
With an ambient temperature of 0 ... 45 °C (32 °F ... 113 °F) | 2.5 A/3.9 A | ||||
Line frequency | 47 ... 63 Hz | ||||
Overload capability | Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s | ||||
Output frequency | 0 ... 550 Hz | ||||
Pulse frequency | 4 kHz (standard), 4 ... 16 kHz (in 2-kHz increments) | ||||
Standard SCCR | 10 kA | ||||
Skipped frequency range | 1, parameterizable | ||||
Converter efficiency | 95 ... 97 % | ||||
Interfaces | Connection to PROFIBUS and PROFINET over the SIMATIC ET 200pro backplane bus Mini USB interface for commissioning via PC (as from STARTER V4.4 plus SSP) Optical interface for commissioning via the IOP-2 Handheld Slot for an optional memory card (SD) for uploading or downloading parameter settings. Facilitates easy device replacement. PTC, bimetal, KTY84, Pt1000 interface for motor temperature monitoring | ||||
Functions | |||||
Open-loop/closed-loop control methods | V/f control – linear (M ~ n) with/without flux current control (FCC), quadratic (M ~ n2) or parameterizable Vector control – sensorless Closed-loop torque control | ||||
Operating functions | Jogging BICO technology Automatic restart following interruptions in operation due to a power failure Smooth connection of converter to rotating motor | ||||
Braking functions | Integrated regenerative feedback functionality Control of an electromagnetic holding brake | ||||
Integrated brake control supplies DC power supply to the brake | |||||
Line voltage | 380 V AC | 400 V AC | 440 V AC | 480 V AC | |
Rectified brake voltage | 171 V DC | 180 V DC | 198 V DC | 216 V DC | |
Recommended brake coil voltage for Siemens motors | 170 ... 200 V DC | 170 ... 200 V DC | 184 ... 218 V DC | 184 ... 218 V DC | |
Disconnection on the DC side permits "fast" braking. | |||||
Protection functions | Undervoltage Overvoltage Ground fault Short-circuit Stall protection Thermal motor protection (I2t or sensor) Converter overtemperature Motor blocking protection Phase failure detection | ||||
Connectable motors | Low-voltage asynchronous (induction) motors Motor cable lengths: max. 15 m (49 ft) (shielded) | ||||
Mechanical specifications | |||||
Degree of protection | IP65 | ||||
Operating temperature | 0 ... 55 °C (32 ... 131 °F) | ||||
Mounting position | Vertical wall mounting (vertical alignment of the cooling fins) | ||||
Dimensions (W × H × D) | 155 mm × 246 mm × 248 mm (6.10 in × 9.69 in × 9.76 in) | ||||
Weight, approx. | 4 kg (8.8 lb) | ||||
Standards | |||||
Certificates of suitability | UL508C, cUL, CE, UKCA, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU | ||||